I-8014W API User Manual, v1.0.1, June 2011
Copyright © 2011 ICP DAS Co., Ltd. All Rights Reserved. E-mail: [email protected]
41
External hardware trigger method
The Magic Scan also accepts external trigger source from the first two terminals, and
with this trigger method, you can set it as rising edge triggered or falling edge
triggered. After setting the external trigger source, triggering condition and starting the
Magic Scan in program, the I-8014W will wait unless it receive the external form Trig+
and Trig- terminals and then start the Magic Scan.