GW-7238D J1939 to MBTCP Server / MBRTU Slave Gateway User’s Manual (Ver.1.1, May. 2013) ---
25
About : Display the GW-7238D utility version.
GW-7238D Status
[1] Interface : Display communication interface.
[2] Error :
Display error status.
[3] Date Created : Display firmware creation date.
[4] Firmware Version: Display firmware version.
Configuration Setting
The Modbus configuration contains the parameters used to control
the behavior of the Modbus serial interface. The parameters are described
as Table 3-1.
All modules on the network must use the same baud/parity/data/stop
bits configuration.
Table 3-1 Modbus Configuration Parameters
Item
Description
Range
Net ID
The ID of the module on the Modbus
network. All modules on the network must
have a unique address.
1~99
Baud Rate The network baud rate.
9600~115200
Parity
The serial communication parity.
NONE / ODD
/ EVEN
Data Bits
The number of data bits used in the serial
communication.
Fixed at 8
Stop Bits
The number of stop bits used in the serial
communication.
1 / 2
IP Address IP Setting.
192.168.255.1
(Default)
Net Mask
Net Mask Setting.
255.255.0.0
(Default)
Gateway
Gateway Setting.
192.168.0.1
(Default)