GT-540P-3GWA-OEM1 user’s manual v1.0
Item Description
Baudrate
The baud rate of the COM2 (RS-485)
Data Bit
The data bit of the COM2
Stop Bit
The stop bit of the COM2
Parity Bit
The parity bit of the COM2
(none, odd, even)
4.4.2
DI/DO Info
(1)
DI
Item Description
Type
The function is used to set the type of DI
channel:
1.
Disable : Disable the linkage function
between DI and DO channels.
2.
DI NO : The DI channel is normal Open.
When the DI channel is close (high), it is
the trigger signal of
GT-540P-3GWA-OEM1.
3.
DI NC:The DI channel is normal close.
When the DI channel is open (low), it is the
trigger signal in the system.
4.
DI Counter: Set the DI channel as counter
mode.
Triggered Hold Time(sec)
This value represents the holding time of the
DI signal for triggering the event. The unit is
second.
(Range : 0 ~ 65535 sec)
Return Hold Time(sec)
When the trigger condition is activated, it
needs to keep the non-trigger status to be
triggered again according to the
“
Return
GT-540P-3GWA-OEM1 user’s manual, Version 1.0, 2013/03
35/52