Single Compare Position
Auto-increment Compare Position
Table 17: Procedure for activating the compare function
7.2.3 Index and Extern Latch
The ECAT-2092T has got two latch inputs for each encoder channel: Index "C" and extern
"HR" latch.
Index latch: The index latch is always enabled and can not be disabled. A index signal
triggers a hardware latch of the current encoder counter. The ECAT-2092T allows the
index latched value to be reset to zero. Assign the 0x1An3 object to the process data
for reading the latched counter value.
Extern latch: The extern latch function supports two modes:
ICP DAS
Page
ECAT-2092T User Manual
Version 1.0
46