background image

 

ACS-11-MF 

User’s Manual (Ver.1.0, Apr./2016) ------------- 2

 

 
Warranty 

All products manufactured by ICP DAS are under warranty regarding 

defective materials for a period of one year from the date of delivery to the 
original purchaser. 
 
Warning 

ICP  DAS  assumes  no liability  for  damages  resulting from  the  use  of 

this product. ICP DAS reserves the right to change this manual at any time 
without  notice.  The  information  furnished  by  ICP  DAS  is  believed  to  be 
accurate and reliable. However, no responsibility is assumed by ICP DAS 
for  its  use,  or  for  any  infringements  of  patents  or  other  rights  of  third 
parties resulting from its use. 
 
Copyright 

Copyright 2016 by ICP DAS. All rights are reserved. 
 

Trademark 

The names used for identification only may be registered trademarks 

of their respective companies. 

 
 

 

 

Document Revision 

 

Version 

Date 

Description of changes 

1.0 

2016/04/18 

First Release Revision 

Summary of Contents for ACS-11-MF

Page 1: ...ACS 11 MF User s Manual Ver 1 0 Apr 2016 1 User s Manual www icpdas com ACS 11 P MF Access Control Reader...

Page 2: ...hange this manual at any time without notice The information furnished by ICP DAS is believed to be accurate and reliable However no responsibility is assumed by ICP DAS for its use or for any infring...

Page 3: ...Software 17 3 1 Installing the eSearch Utility 17 3 2 Using the eSearch Utility to Assign an IP Address 17 3 3 Web Configuration 20 3 3 1 IP Address Configuration 21 3 3 2 Reader Configuration 23 3 3...

Page 4: ...ACS 11 MF User s Manual Ver 1 0 Apr 2016 4 4 2 10 Configure System Time 36 4 2 11 Check Door Position 37 4 3 CRC Calculation CCITT 16 37...

Page 5: ...ely enhance the service quality of management The ACS 11P MF has integrated Power over Ethernet PoE it allows power and data to be carried over a single Ethernet cable so a device can operate solely f...

Page 6: ...ction Provides access records Max card capacity 8000 cards Supports elevator floor control max 16F 1 2 Applications 1 3 Specifications Table 1 1 System Specifications Models ACS 11 MF ACS 11P MF CAN B...

Page 7: ...ement SPDT Contact Rating 6A 125 250VAC RFID Supported Card Mifare S50 Standard ISO 14443 A Power Reverse Polarity Protection Yes Powered from CN1 Connector 10 30 VDC Powered from PoE Yes IEEE 802 3af...

Page 8: ...ndicator System Status Indicator LED Module Status LED Status Default IP operation mode Blink per 100 ms Camera control module connection failed Blink per 1000 ms Elevator control module 1 connection...

Page 9: ...in Assignment Description CN1 GND VDC Power 10V 30 VDC CN2 DI0 G DI1 G DI2 G DI3 G DI0 Door position detection DI1 Electric lock trigger DI2 3 n a Digital Input Dry Contact CN3 COM NO NC Anti sabotage...

Page 10: ...ignment Description CN1 D D RS 485 D D Baud Rate bps 9600 Parity NONE Data Bits 8 Stop Bits 1 CN2 DI0 G DI1 G DI0 Door position detection DI1 Electric lock trigger Digital Input Dry Contact NC COM CN3...

Page 11: ...pecifications for any custom enclosures All dimensions are in millimeters Figure 2 4 Dimension of the ACS 11 P MF Module 2 4 Hardware Connections 2 4 1 Power and I O wiring architecture ACS 11 P MF se...

Page 12: ...ACS 11 MF User s Manual Ver 1 0 Apr 2016 12 Figure 2 5 ACS 11 MF Power and I O wiring architecture Figure 2 6 ACS 11P MF Power and I O wiring architecture...

Page 13: ...inated by two terminal resistors 120 for proper operation as shown in the below figure Figure 2 8 Terminal Resistor Therefore the ACS 11 MF module supplies a jumper for users to active the terminal re...

Page 14: ...s to make the product enters Firmware update mode please refer to the following settings mode When ACS 11 P MF is in firmware update mode the RF LED will blink per 500 ms Users can update the firmware...

Page 15: ...p3 Establish a network connection between PC and ACS 11 P MF Step4 Launch the firmware update tool FW_Update_Tool_v2 00 exe 1 Select the connection network interface of ACS 11 P MF 2 Set IP address as...

Page 16: ...ACS 11 MF User s Manual Ver 1 0 Apr 2016 16 Figure 2 10 Firmware update process...

Page 17: ...panion CD at CD Napdos Software eSearch Or from the ICP DAS FTP site at http ftp icpdas com pub cd tinymodules napdos software esearch Step 2 Follow the instructions in the Setup Wizard to complete th...

Page 18: ...tton the utility will perform a search of all ACS 11 MF modules on your network Step 3 Click the ACS 11 MF item for which you want to change the IP setting and then click the configuration UDP button...

Page 19: ...rmation Modify the network settings as necessary and then click the OK button The ACS 11 MF series module will use the new settings immediately ACS 11 MF doesn t support DHCP function Step 5 After sav...

Page 20: ...Explorer are reliable and popular internet browsers that can be used to configure ACS 11 MF series module Step 2 Enter the URL address for the ACS 11 MF If you haven t changed the default IP address...

Page 21: ...ardware and software including the Firmware version MAC Address and IP Address etc 3 3 1 IP Address Configuration Clicking the IP Config tab will display the network and control I O connection setting...

Page 22: ...a specific IP address Default 192 168 0 1 Mask This parameter is used to assign the subnet mask for the ACS 11 MF device The subnet mask indicates which portion of the IP address is used to identify t...

Page 23: ...IP address of the ET 7067 that can control the elevator 1F to 8F for building floor control Default 192 168 2 1 IP2 9 16F This parameter is used to assign a specific IP address of the ET 7067 that can...

Page 24: ...0001 Range 1 65535 Reader Name The module information indicates the name of the alias that is used to identify the module Installation location The module information indicates the installation locati...

Page 25: ...iption RTC Calibration Reference computer time to set the system time of the module 3 3 4 Change Password Configuration Clicking the Change Password tab will display the settings page allowing you cha...

Page 26: ...following link and install on computer XAMPP is an easy to install Apache distribution containing MySQL PHP http sourceforge net projects xampp files XAMPP 20Windows Note Windows XP or Windows 2003 I...

Page 27: ...MF User s Manual Ver 1 0 Apr 2016 27 04 Launch XAMPP control panel and start Apache and MySQL service 05 Entry MySQL management environment 06 Import database file of access control system acs sql 2 3...

Page 28: ...nfiguration and connection a Entry the IP address as 192 168 0 x where x is a number between 1 and 254 except 1 Subnet mask as 255 255 0 0 Finally press OK button b Establish a network connection betw...

Page 29: ...ication Program RFIDCardReader_DB exe a Fill and Add ACS 11 MF IP address 192 168 0 1 a Fill card UID 2632528336 b Fill voice number 0 c Select ACS 11 MF IP address 192 168 0 1 d Fill floor control se...

Page 30: ...ram will automatically add the card UID to the ACS 11 MF a2 Place the Mifare card close to the ACS 11 MF a3 ACS 11 MF will read the card UID and return to database via Door Access Control Communicatio...

Page 31: ...tion Code Data Length UID 8 byte Reserve 1 byte Elevator Floor Selection 2 byte Elevator Floor Open Time 1 byte Voice Code 2 byte Reserve 2 byte CRCH CRCL 0x05 0x10 0x01 0x00 0x01 UID 0x9CEBA860 00000...

Page 32: ...s less than 8 bytes please fill the remaining data fields to zero Response Success Function Code Data Length Result CRCH CRCL 0xAF 0x01 0x01 Response Fail Function Code Data Length Result CRCH CRCL 0x...

Page 33: ...C UID 0x9CEBA860 2632689760 if the data length is less than 8 bytes please fill the remaining data fields to zero Elevator Floor Selection 0xFF 0xFF 1 8F 9 16F Voice Code 0x30 0x37 The 07 Voice Code R...

Page 34: ...to zero Elevator Floor Selection 0x80 0x01 1 8F 9 16F Elevator Floor Open Time 0x05 5 Second Voice Code 0x30 0x37 The 07 Voice Code Response Success Function Code Data Length Result CRCH CRCL 0xAF 0x...

Page 35: ...ccess Function Code Data Length Result CRCH CRCL 0xAF 0x01 0x01 Response Fail Function Code Data Length Result CRCH CRCL 0xAE 0x01 0x01 4 2 8 Inquire Access Record Function Code Data Length Reserve 2...

Page 36: ...9 Delete Access Record Function Code Data Length Reserve 2 byte CRCH CRCL 0x28 0x02 0x52 0x54 Response Success Function Code Data Length Result CRCH CRCL 0xAF 0x01 0x01 Response Fail Function Code Da...

Page 37: ...ion Code Data Length Status CRCH CRCL 0xAF 0x01 Status 1 Close 2 Open 4 3 CRC Calculation CCITT 16 C Example public static byte HexStringToByteArray string hexString if hexString Length 4 hexString 0...

Page 38: ..._Init 0xFFFF for int i 0 i DataLength i CRC_Init CRC_Init uint data i 8 for int j 0 j 8 j if System Convert ToBoolean CRC 0x8000 CRC_Init CRC_Init 1 CRC_Polynomial else CRC_Init CRC_Init 1 return HexS...

Page 39: ...find out IP address of ACS 11 MF 1 Entry the default IP operation mode Step1 Press and hold the No 1 key Step2 Reset the power of ACS 11 MF Step3 Now the PWR led flashes and IP address is 192 168 0 1...

Reviews: