16
Turbos require only standard single phase power, one flow and one return water pipe and a data
cable (supplied) to connect to the wall mounted remote control touch screen. The pump must also be
connected to the electronic side of the Turbo and works must be completed by a certified electrician,
builder or installer. Improper installation or operation may result in equipment damage not covered by
warranty.
Power Connection
Power Connection
Electric Power Input Recommendations
A certified electrician should connect the Main Power of your
machine.
For Europe, China, Asia, S.E Asia, Africa, India, The Middle East
and Australia Turbos require only a single phase 208-240 volt
supply @ 50Hz or 60Hz. The maximum load is 20 amps and the
typical operating load varies from 8 to 16 amps. An RCD safety
device is built in to the machine, however it is recommended
that the building fuse also incorporates an RCD Please avoid
the use of long extension cords as they may result in voltage
drops that may trigger the inbuilt safety system.
For the USA, Canada, South America and Japan, voltages from
208 to 240 volts are generally readily available on the local
power grid and can be provided to most buildings, in fact
many houses and buildings in these countries already have
higher voltage between 208 & 240 volts connected for high
current devices such as clothes dryers, etc. Higher voltages are
more efficient and provide better performance for high power
products like Turbo machines.
Turbos must be connected to the voltage marked on the
machine,
/!\ they are NOT multi-voltage and using a
different voltage may cause severe damage
.
Your Turbo is fitted with an electrical safety device to protect
users and all AC power connections used must have an earth
connection that complies with your local electrical safety
regulations.
Screen Connection
The Remote Control Touch Screen with Wall Mounting Box can
be positioned anywhere within 40 meters of the Turbo. It must
be mounted in a dry place and comes with a multi world voltage
power supply that requires 100-240 volt 10 amp single phase
power supply.
The screen is connected to the Turbo by a single twisted pair
cable (provided). The default factory pre-wired control cable
provided by iCool is 20 meters. If further length is required,
this can be obtained at any local electronics store (twisted pair
cable).
A certified electrician must do the wiring. See wiring
instructions in Pages 18-19.
Pump Connection
The water flow pump i controlled by the TurboCool electronics
for safety. The QB035 Davey Water Circulation Pump must be
wired to the electronic side of your Turbo. A certified electrician
must do the wiring. See wiring instruction in Pages 20-21.
Please note: the pump needs to be the same voltage as the
Turbo unit.
Summary of Contents for 5 Series
Page 1: ...Series 5 Owner s Manual Turbo Range www icoolsport com support icoolsport com ...
Page 2: ......
Page 4: ...Your Turbo O1 ...
Page 10: ...Quick Setup O2 ...
Page 22: ...Get Started O3 ...
Page 28: ...SafetyProcedures O4 ...
Page 32: ...TechnicalSupport O5 ...
Page 33: ......
Page 40: ......