PM2L-R
Input / Control Panel
Mute Controls
PM2l-R
Power Control Panel
Power On / Off
AC Power Connecto
r
Powercon locking connector
Overdrive LED
Flashes red when the amplifiers
protective circuitry is engaged
Signal LED
Flickers when an audio signal of at
least -30
dBu is present
Secondary Analog - AES/EBU
Input/Output
Can be configured for “priority
override”
Primary & Secondary
Ethernet Inputs
RJ-45 female;when both
are connected, change-
over to Secondary is
automatic if Primary fails.
Yellow LED flashes when
the connector is active,
glows steadily when data
is streaming. Green LEDs
glow when connected but
inactive, turn Orange to
indicate a faulty connec-
tion.
Primary Analog - AES/
EBU Input/Output &
Looping Output
XLR female; pin 1 chassis,
pin 2 +, pin 3 -
Push Button Volume Controls
Also function as a manual
Standby/On
control
Input Pad & LED Indicator
On / Off 10 dB pad for Primary Analog Input; allows input signals
of up to +24 dBu when inserted. Input Clip LED flashes red
when the Primary Analog Input preamplifier is being overdriven.
AES/EBU Input Switch
When On, turns analog input 1
into an AES/EBU input
Power LED
Glows when amplifier
power is On
Thermal LED
Lights to indicate that an over-
temperature sensor has shut
down the amplifier
Push-To-Reset
Circuit Breakers
65
Users Manual
IC
2