9
1. General Notes
This Heat Design gas appliance is a High Efficiency, Balanced Flue Live Fuel Effect appliance. It provides radiant
and convected heat using the latest burner technology. As well as having a variable heat output, these fires also
utilise a special control system that allows the appliance to use three burners for high output or a single burner
for lower outputs.
One of the burners will be designated as the "Main" Burner, this is the Centre, The second and third burners will
be designated as the "Effect" Burners. The Effect burners can be switched ON or Off whilst the appliance is
alight.
Before Installation, check that the local distribution conditions, nature of the gas and pressure, and adjustment
of the appliance are compatible.
This appliance is intended for use on a gas installation with a governed meter.
This Gas Installation may only be installed by a registered professional competent person (A Qualified Gas
Engineer in IE and UK). The installation must adhere to the requirements of the local and national Building
regulations and national standards. The installation manual must also be followed.
Ensure that the Flue Terminal is not in any way obstructed and is clear of vegetation, i.e. trees, shrubs etc. and
that no objects are leant against the terminal or guard.
Always clean the Window Panel before the fire is ignited. Any finger prints must be removed, as
these will be burnt into the glass and will be un-removable.
Do not operate this appliance if the glass panel has been broken (or cracked), removed or is open.
The appliance is designed to fit numerous installation situations as listed in these installation instructions.
However only flue approved by Heat Design for this appliance may be used.
This appliance is a balanced flue product and is room sealed and as such requires no additional ventilation for
operation. However an adequate supply of fresh air to maintain temperatures and a comfortable environment is
recommended.
This appliance is designed as a heating appliance, and as such will get very hot in operation; all surfaces (except
the controls and access door) are considered to be working surfaces and as such should not be touched. The
front windows and surrounds are not considered to be fully secure guards against accidental contact. It is
recommended that an approved fire screen be used if children, the elderly or persons with limited mobility are
to be present in the same area.
Do not place curtains, laundry, furniture etc. within a safe distance of 300mm of this appliance.
Do not attempt to burn rubbish on this appliance.
If this appliance is extinguished, on purpose or other, no attempt to relight should be made within 3 minutes.
Summary of Contents for 1100 Bay
Page 3: ...3 Iconic 1100 Bay ICONIC1100 3S ...
Page 4: ...IE GB 4 Iconic 1100 Corner Left Right IC1100 CL CR ...
Page 5: ...5 Iconic 1100 Room Divider ICONIC1100 RD ...
Page 6: ...IE GB 6 Iconic 1100 See Through IC1100 ST ...
Page 19: ...19 3 3 3 Mantel Clearances 3 3 3 a Combustible Mantel Side view ...
Page 20: ...IE GB 20 ...
Page 21: ...21 3 3 3 b Combustible Mantel Side Wall Top view ...
Page 25: ...25 Horizontal Wall Vent Termination Category 1 for 200 130 type C11 ...
Page 27: ...27 Typical Installations ...
Page 32: ...IE GB 32 ...
Page 34: ...IE GB 34 3 5 5 Iconic 1100 Pebble Effect ...
Page 43: ...43 Annex 1 ...
Page 44: ...IE GB 44 ...
Page 45: ...45 ...
Page 46: ...IE GB 46 ...
Page 47: ...47 ...