5

Setup Menu – Pipe Parameter

Press

 

to 

display:

  

, Select 0.Pipe parameter, then

 

The following options are available (

using the

 

 or 

 buttons)

1.

Outer diameter

2.

Wall thickness

3.

Material: 

Press

 

to choose between 

PVC, Carbon  steel, Steel, 

 Copper pipe.

3. Fluid type:

 Press

 

or

 

to choose between

 Water,Sea Water,Oil...etc.

Setup Menu – System setting

Press

, Select 1.System  setting, then

 

to 

display:

The following options are available (

using the

        or

        

buttons)

 

0.

System Unit

Press

  or     

to choose between 

 Metric, English.

 

1.

 Flow Rate Unit

Press           

 

or 

to choose between

  m3/h, LPM, GPM.

 

2. 

Total Unit

Press        

 

or       

to choose between

 m3, L, GAL.  

3.

Totalizer Reset

:  Press

 then press the

 

 

or 

arrow to select 

'YES' or 'NO'. 

If

 'YES' is selected

,

 parameters will be reset . 

4.

Time Set

Generally,  it  is  unnecessary  to  modify  date 

time  as  the  system  is  provided  with  a  highly 

reliable perpetual calendar chip.

5.

System Lock

Once the system is locked, any modifications to the system are 

prohibited, but the parameter is readable. “Unlock” using your 

designated password.

- 5 -

 or 

Summary of Contents for truflo Ultraflo UF500

Page 1: ...Ultraflo UF500 Instruction Manual...

Page 2: ......

Page 3: ...Content Product Components 1 Installation and Connection 2 Panel Function 3 Powering On 3 Keypad Functions 3 Display Descriptions 4 Dimensions 8...

Page 4: ...Display Cable Base Bracket Upper Bracket Instruction manual Coupling Agent Instruction Manual F5 1 Notice Thank you for choosing UF 500 Series Flow Meter This instruction manual contains the important...

Page 5: ...rside of the pipe Step3 Slowly remove the protective cover off the sensor Step5 Connect the M cable Step2 Align the upper bracket to the pipe position Using the mounting screws connect the upper and t...

Page 6: ...99 represents that no signal is being detected while 99 represents the GPM Gal 0 F maximum signal strength Keypad functions Follow these guide lines when using the Flow meter keypad Press to enter th...

Page 7: ...onthly Total Yearly Total Press to return to previous menu Display Run time Date Month and Year Net Total Setup Menu Press to display Setup menu The following options are available using the or button...

Page 8: ...available using the or buttons 0 System Unit Press or to choose between Metric English 1 Flow Rate Unit Press or to choose between m3 h LPM GPM 2 Total Unit Press or to choose between m3 L GAL 3 Total...

Page 9: ...Calibration and then and to display 4mA set point Use and to set 4mA After 4mA is set press to move to your 20mA set point Once 20mA is set press to move to next screen 2 Set Zero Press reset Zero Poi...

Page 10: ...cation on the display will be zero This function can prevent the flow meter from reading flow after a pump is shut down but there is still liquid movement in the pipe which would result in a flow tota...

Page 11: ...mm B mm C mm D mm Model min max 25 25 28 5 29 5 36 41 1 5 25 58 58 58 68 78 91 1 5 32 1 5 38 4 5 28 4 5 35 8 5 45 8 15 18 5 24 27 32 1 5 20 1 5 48 1 5 58 8 23 8 5 54 5 64 sales iconprocon com support...

Reviews: