Icon Process Controls truflo Ultraflo UF500 Instruction Manual Download Page 6

3

Panel 

Powering  n

the 

self-diagnosis program 

Mounting  screw

M16 

OLED display screen

Signal Quality (SQ value) 

Q value   Signal Quality. 

indicates the 

level of the 

signal detected. 

Q value is indicated by numbers from 0  99

 represents that no signal is being detected while 99 represents the 

GPM

G a l

0

F

maximum signal strength

Keypad functions

Follow these guide lines when using the Flow meter keypad:

Press

 

 to enter the Programming Mode or to return to the previous 

menu during programming.

Press

 

     to scroll up or down 

Press

  

Press 

    to  select  digits  (0-9) 

Press

       to confirm selection.

to move to the next digit  

Mounting  screw

Keypad

Model

Summary of Contents for truflo Ultraflo UF500

Page 1: ...Ultraflo UF500 Instruction Manual...

Page 2: ......

Page 3: ...Content Product Components 1 Installation and Connection 2 Panel Function 3 Powering On 3 Keypad Functions 3 Display Descriptions 4 Dimensions 8...

Page 4: ...Display Cable Base Bracket Upper Bracket Instruction manual Coupling Agent Instruction Manual F5 1 Notice Thank you for choosing UF 500 Series Flow Meter This instruction manual contains the important...

Page 5: ...rside of the pipe Step3 Slowly remove the protective cover off the sensor Step5 Connect the M cable Step2 Align the upper bracket to the pipe position Using the mounting screws connect the upper and t...

Page 6: ...99 represents that no signal is being detected while 99 represents the GPM Gal 0 F maximum signal strength Keypad functions Follow these guide lines when using the Flow meter keypad Press to enter th...

Page 7: ...onthly Total Yearly Total Press to return to previous menu Display Run time Date Month and Year Net Total Setup Menu Press to display Setup menu The following options are available using the or button...

Page 8: ...available using the or buttons 0 System Unit Press or to choose between Metric English 1 Flow Rate Unit Press or to choose between m3 h LPM GPM 2 Total Unit Press or to choose between m3 L GAL 3 Total...

Page 9: ...Calibration and then and to display 4mA set point Use and to set 4mA After 4mA is set press to move to your 20mA set point Once 20mA is set press to move to next screen 2 Set Zero Press reset Zero Poi...

Page 10: ...cation on the display will be zero This function can prevent the flow meter from reading flow after a pump is shut down but there is still liquid movement in the pipe which would result in a flow tota...

Page 11: ...mm B mm C mm D mm Model min max 25 25 28 5 29 5 36 41 1 5 25 58 58 58 68 78 91 1 5 32 1 5 38 4 5 28 4 5 35 8 5 45 8 15 18 5 24 27 32 1 5 20 1 5 48 1 5 58 8 23 8 5 54 5 64 sales iconprocon com support...

Reviews: