Installed into non-combustible material ONLY;
•
All gas connections or pipelines near your new Burner installation must be
disconnected and made safe by an appropriately qualified professional prior to
installation;
•
Installed into a fixed, level and secure position before filling, lighting and
operating;
•
Installed in a position that limits relocation requirements to eliminate the risk of
accidents caused by fuel spillage. These Burners are not designed to be
relocated frequently;
•
Installed into a level platform;
•
Not installed directly beside or near wallpaper, laminate, veneer or any surface
that has not been fire rated and considered combustible.
•
A minimum of 1000mm radius to any combustible material.
•
Not be within the reach of any objects that are not fixed in position and can be
moved by the wind or bumped over easily i.e. curtains, blankets, newspapers
etc.
Installation Clearances
Burner Clearances
TO COMBUSTIBLE MATERIALS
TO NON-COMBUSTIBLE MATERIALS
A
B
C
D
A
B
C
D
SB500
1000mm
1000mm
2000mm
2000mm
50mm
50mm
500mm
500mm
SB800
1000mm
1000mm
2000mm
2000mm
50mm
50mm
500mm
500mm
SB1100
1000mm
1000mm
2000mm
2000mm
50mm
50mm
500mm
500mm
SB1400
1000mm
1000mm
2000mm
2000mm
50mm
50mm
500mm
500mm