5 - 1
SECTION 5 ADJUSTMENT PROCEDURES
5-1 PREPARATION
When adjusting IC-F50/F51, the optional CS-F50 ADJ
ADJUSTMENT SOFTWARE
(Rev. 1.0 or later), *OPC-966
JIG CABLE
(modified
OPC-966
CLONING CABLE
) are required.
REQUIRED TEST EQUIPMENT
SYSTEM REQUIREMENTS
• Microsoft
®
Windows
®
95/98/ME
• RS-232C Serial port (DB9)
ADJUSTMENT SOFTWARE INSTALLATION
q
Boot up Windows.
- Quit all applications when Windows is running.
w
Insert the cloning software CD-ROM into the appropriate
CD-ROM drive.
e
Select ‘Run’ from the [Start] menu.
r
Type the setup program name using the full path name,
then push [Enter] key.
(For example; D:\Setup.exe)
t
Follow the prompts.
y
Program group ‘CS-F50 ADJ’ appears in the ‘Programs’
folder of the [Start] menu.
BEFORE STARTING SOFTWARE ADJUSTMENT
Clone the adjustment frequencies, listed in page 5-2, into
the transceiver using with the CS-F50 before starting the
software adjustment. Otherwise, the transceiver can not
start software adjustment.
CAUTION!:
BACK UP the originally programed memory
data in the transceiver before progaming the
adjustment frequencies.
When program the adjustment frequencies
into the transceiver, the transceiver’s memory
data will be overwritten and lose original
memory data at the same time.
STARTING SOFTWARE ADJUSTMENT
q
Connect IC-F50/F51 and PC with *OPC-966
JIG CABLE
.
w
Turn the transceiver power ON.
e
Boot up Windows, and click the program group ‘CS-F50
ADJ’ in the ‘Programs’ folder of the [Start] menu, then
CS-F50 ADJ’s window appears.
r
Click ‘Connect’ on the CS-F50’s window, then appears
IC-F50/F51’s up-to-date condition.
t
Set or modify adjustment data as desired.
Microsoft and Windows are registered trademarks of
Microsoft Corporation in the U.S.A. and other countries.
EQUIPMENT
GRADE AND RANGE
EQUIPMENT
GRADE AND RANGE
DC power supply
Output voltage : 7.2 V DC
Current capacity : 3 A or more
Audio generator
Frequency range : 300–3000 Hz
Output level : 1–500 mV
FM deviation meter
Frequency range : DC–300 MHz
Measuring range : 0 to ±10 kHz
Attenuator
Power attenuation : 40 or 50 dB
Capacity : 10 W or more
Frequency counter
Frequency range : 0.1–300 MHz
Frequency accuracy : ±1 ppm or better
Sensitivity : 100 mV or better
Standard signal
generator (SSG)
Frequency range : 100–300 MHz
Output level : 0.1 µV to 32 mV
(–127 to –17 dBm)
Digital multimeter
Input impedance : 10 M
Ω
/V DC or more
DC voltmeter
Input impedance : 50 k
Ω
/V DC or more
RF power meter
(terminated type)
Measuring range : 1–10 W
Frequency range : 100–300 MHz
Impedance : 50
Ω
SWR : Less than 1.2 : 1
Oscilloscope
Frequency range : DC–20 MHz
Measuring range : 0.01–20 V
AC millivoltmeter
Measuring range : 10 mV to 10 V
Summary of Contents for VHF IC-F50
Page 1: ...SERVICE MANUAL ADDENDUM CONTENTS PARTS LIST 1 BOARD LAYOUTS 6 VOLTAGE DIAGRAM 8 Feb 2008...
Page 10: ...SERVICE MANUAL ADDENDUM CONTENTS PARTS LIST 1 BOARD LAYOUTS 6 VOLTAGE DIAGRAM 8 Aug 2007...
Page 20: ...S 1407IZ C1 e Dec 2006 VHF TRANSCEVER...
Page 57: ...1 1 32 Kamiminami Hirano ku Osaka 547 0003 Japan S 14007IZ C1 e 2003 2006 Icom Inc...