1-1-32 Kamiminami, Hirano-ku, Osaka 547-0003, Japan
A-7046W-4EX
Printed in Japan
© 2012 Icom Inc.
(You can download the Instruction Manual from the Icom web site; http://www.icom.co.jp/world/.)
For your information
The setting data or firmware can be automatically loaded
into the VE-PG3 from a USB memory.
It is useful to recover the configuration or to update the
firmware.
• The USB memory is not supplied. Purchase separately.
• See the VE-PG3 instruction manual for details.
About the USB memory
• A USB memory such as one with biometric authentication, or
one with password protection is not supported.
• Turn OFF the VE-PG3's power before inserting or removing
the USB memory, to prevent data corruption.
• Either one of the USB slots accepts the USB memory, but
insert only one USB memory at a time.
• Inser the USB memory securely.
• NEVER remove the USB memory or turn OFF the VE-PG3's
power, while transferring data. It will cause data corruption,
or damage the USB memory.
• After the firmware updating is finished, check the firmware
version on the setting screen to verify that the update was
correctly done.
• When importing setting data from the USB memory to
the VE-PG3, the originally programmed setting data is
automatically saved as “bakdata.sav” in the USB memory, as
a backup.
Turn OFF the VE-PG3’s power,
and then insert the USB memory securely.
Then, turn ON the power again.
Automatic setting data load with a USB memory
About the LED indication
(See the "PRECAUTIONS" leafl et about the <INIT> and <UPDATE> buttons.)
Front view
<UPDATE> button
[WAN] LED
[EXT] (1/2) LED
[PWR/MSG] LED
[V/RolP] LED
[D-TRX] LED
[TRX] (1/2) LED
[USB] port
(USB2.0)
About the setting screen
• See the VE-PG3 instruction manual for details.
e
Setting screen
Displays the settings and values when you click the screen
name.
r
Setting buttons
Save or cancel setting values.
If “Items that need to be restarted have changed.” is dis-
played on the screen when you click the [Apply] button, click
the [OK] button.
The VE-PG3 reboots, and the setting items and values are
updated.
The following message is displayed on the screen while the
VE-PG3 is rebooting.
• If the setting screen does not automatically return, click [Back]
about 30 seconds after the “Now rebooting.” message appears.
• Items and buttons may differ, depending on the setting.
q
Link to the Icom web site
Click the Icom logo to open the Icom web site if your PC is
connected to the Internet.
w
Setting menu
Displays the screen name list on a menu line. When you
click each menu title, a list of items drops down which you
can use to select the desire setting item.
LED
Indication
In the Converter mode
In the Bridge mode
PWR/MSG
Doesn't light
Power is OFF
Green
Lights
Power is ON
Blinks
Booting
Red
Lights
–
Blinks
–
Orange
Lights
A firmware update is ready./Downloading new firmware.
Blinks
Accessing the USB memory.
(While loading the setting file or updating the firmware.)
Booting
Initialization is in progress. (Green and Orange LEDs alternately light.)
Firmware update is in progress.
WAN
Doesn't light
No network connection./Connecting to the network is in progress.
Green
Lights
Connected to the WAN line. (An IP address has been obtained.)
Blinks
The WAN line is communicating.
Red
Lights
–
Blinks
Authentication error/failed (PPPoE)
Failed to obtain IP address (DHCP) (Time-out timer: 30 seconds)
Orange
Lights
–
Blinks
–
V/RoIP
Doesn't light
No registration
Not connected
Green
Lights
Registration succeed (All entries)
Connected
Blinks
The line is communicating.
Red
Lights
–
Blinks
1 or more registrations failed.
Orange
Lights
–
Blinks
–
D-TRX*
Doesn't light
No transceiver is connected, or it is turned OFF.
Green
Lights
Receiving an audio signal.
Blinks
–
Red
Lights
Sending an audio signal.
Blinks
–
Orange
Lights
The transceiver is communicating.
Blinks
–
TRX1
TRX2
Doesn't light
No transceiver is connected, or it is turned OFF.
Green
Lights
Receiving an audio signal.
Blinks
–
Red
Lights
Sending an audio signal.
Blinks
–
Orange
Lights
The transceiver is communicating.
Blinks
–
EXT1
EXT2
Doesn't light
No input or output signal.
Green
Lights
Input is busy.
Blinks
–
Red
Lights
Output is busy.
Blinks
–
Orange
Lights
Input or output is busy.
Blinks
–
*For the operation using an IC-FR5000/FR6000.
• All indicators light while updating the fi rmware or rebooting.
• The indication may differ, depending on the setting.
q
w
r
e