Selected or unselected VFO’s operating mode and
filter
Command:
26
L
If you omit the data mode or filter setting, default setting
is automatically applied.
q
Receive mode
e
Filter setting
w
Data mode setting
00: Fixed
X X X X X X
0 0
q
Receiving mode
w
Data mode
e
Filter
00:LSB
11:S-AM(D)
00:Fixed
01:FIL1
01:USB
14:S-AM(L)
02:FIL2
02:AM
15:S-AM(U)
03:FIL3
03:CW
16:P25
04:FSK
17:D-STAR
05:FM
18:dPMR
06:WFM
19:NXDN-VN
07:CW-R
20:NXDN-N
08:FSK-R
21:DCR
Scope waveform data
Command:
27 00
Outputs the waveform data to the controller.
q
w
e
r
t
y
u
00: Fixed
• • •
X X X
0 0
X X X X X X X X X
X X
w
Division number (NOW): 01 ~ 11
e
Division number (Maximum): 11 (USB)
When sent through the USB port, the data is divided by 11
and sent in sequential order.
L
The divided data is not output from [LAN].
The division number (Maximum) means the maximum
divided number.
The division number (Now) means the number that
indicates the divided data location.
Example: Sending the 5th data of divided into 11.
The division number (Now) is "5," and the division
number (Maximum) is "11."
L
The 1st data sends only the wave information (
q
~
y
)
without the waveform data (
u
).
The 2nd or later data sends the minimum wave
information (
w
~
e
) with waveform data (
u
).
r
Center or Fixed mode data
00: Center mode scope
01: Fixed mode scope
t
Waveform information
The waveform information is different between Center
mode and fixed mode.
In the Center mode: Center frequency and span are sent.
Scope span setting (in the Center
mode (
w
~
y
)
In the Fixed mode: Lower edge and higher edge
frequencies are sent.
Scope Fixed edge frequency settings
(
e
~
!2
y
Out of Range
00: In range
01: Out of range
L
If the scope data is out of range, the waveform data (
u
)
is not obtained.
u
Waveform data
Data range: 0 ~ 160
Data length: 475
D
Command formats (Continued)
Remote control
21