5-6
ADJUSTMENT ITEM
ADJUSTMENT CONDITIONS
OPERATION
VALUE
SENSITIVITY
• Connect a Standard Signal Generator to the antenna connector.
118.020 MHz
(Band A)
[LT1]
1
Set the SSG as:
Frequency:
(Displayed)
Modulation:
None
Level:
0 dBµ (–107 dBm)
Touch
[ENT]
.
(Automatic
adjustment)
(Band B)
[LT1]
2
146.020 MHz
(Band A)
[MT1]
3
Set the SSG as:
Frequency:
(Displayed)
Modulation:
None
Level:
0 dBµ (–107 dBm)
(Band B)
[MT1]
4
173.980 MHz
(Band A)
[HT1]
5
Set the SSG as:
Frequency:
(Displayed)
Modulation:
None
Level:
0 dBµ (–107 dBm)
(Band B)
[HT1]
6
375.020 MHz
(Band A)
[LT4]
7
Set the SSG as:
Frequency:
(Displayed)
Modulation:
None
Level:
0 dBµ (–107 dBm)
(Band B)
[LT4]
8
420.020 MHz
(Band A)
[MT4]
9
Set the SSG as:
Frequency:
(Displayed)
Modulation:
None
Level:
0 dBµ (–107 dBm)
(Band B)
[MT4]
10
449.980 MHz
(Band A)
[HT4]
11 Set the SSG as:
Frequency:
(Displayed)
Modulation:
None
Level:
0 dBµ (–107 dBm)
(Band B)
[HT4]
12
450.020 MHz
(Band A)
[LT5]
13 Set the SSG as:
Frequency:
(Displayed)
Modulation:
None
Level:
0 dBµ (–107 dBm)
(Band B)
[LT5]
14
500.020 MHz
(Band A)
[MT5]
15 Set the SSG as:
Frequency:
(Displayed)
Modulation:
None
Level:
0 dBµ (–107 dBm)
(Band B)
[MT5]
16
549.980 MHz
(Band A)
[HT5]
17 Set the SSG as:
Frequency:
(Displayed)
Modulation:
None
Level:
0 dBµ (–107 dBm)
(Band B)
[HT5]
18
M
RECEIVE SENSITIVITY ADJUSTMENT
1) Select the adjustment item by rotating
Band A [DIAL]
.
2) Set or modify the adjustment value as specifi ed, by rotating
Band B [DIAL]
.
3) Touch
[ENT]
to store the value.
5-4 RECEIVE ADJUSTMENTS