![Icom ID-5100A Service Manual Download Page 23](http://html1.mh-extra.com/html/icom/id-5100a/id-5100a_service-manual_2038177023.webp)
5-5
ADJUSTMENT ITEM
ADJUSTMENT
CONDITIONS
OPERATION
VALUE
144 MHz Band
DV DEVIATION
(Band Low)
[MDS]
1 • Connect a modulation
analyzer with an oscil-
loscope to the antenna
connector, through an
attenuator, and set it as:
HPF:
OFF
LPF:
20 kHz
De-emphasis:
OFF
Detector:
(P–P)/2
• No audio applied.
• Transmitting
Rotate
Band B [DIAL]
to ad-
just the deviation, and then
touch
[ENT]
during transmit.
±1.05 kHz
(Band Center)
[MDS]
2
(Band High)
[MDS]
3
144 MHz Band
DV MODULATION BALANCE
(Band Low)
[MDB]
1
Minimum
deviation
(Band Center)
[MDB]
2
(Band High)
[MDB]
3
430 MHz Band
DV DEVIATION
(Band Low)
[MDS]
1
±1.05 kHz
(Band Center)
[MDS]
2
(Band High)
[MDS]
3
430 MHz Band
DV MODULATION BALANCE
(Band Low)
[MDB]
1
Minimum
deviation
(Band Center)
[MDB]
2
(Band High)
[MDB]
3
144 MHz Band
CTCSS DEVIATION
(FM)
[MCT]
1 • Connect a modulation
analyzer with an oscil-
loscope to the antenna
connector, through an
attenuator, and set it as:
HPF:
OFF
LPF:
20 kHz
De-emphasis:
OFF
Detector:
(P–P)/2
• No audio applied.
• Transmitting
Rotate
Band B [DIAL]
to ad-
just the deviation, and then
touch
[ENT]
during transmit.
±0.75 kHz
(FM-N)
[MCT]
2
(Set the
same value
as the FM
mode.)
430 MHz Band
CTCSS DEVIATION
(FM)
[MCT]
1
±0.75 kHz
(FM-N)
[MCT]
2
(Set the
same value
as the FM
mode.)
144 MHz Band
DTCS DEVIATION
(FM)
[MDT]
1
±0.75 kHz
(FM-N)
[MDT]
2
(Set the
same value
as the FM
mode.)
430 MHz Band
DTCS DEVIATION
(FM)
[MDT]
1
±0.75 kHz
(FM-N)
[MDT]
2
(Set the
same value
as the FM
mode.)
M
DEVIATION ADJUSTMENT (continued)
1) Select the adjustment item by rotating
Band A [DIAL]
.
2) Set or modify the adjustment value as specifi ed, by rotating
Band B [DIAL]
.
3) Touch
[ENT]
to store the value.