![Icom ID-5100A Service Manual Download Page 20](http://html1.mh-extra.com/html/icom/id-5100a/id-5100a_service-manual_2038177020.webp)
5-2
ADJUSTMENT ITEM
ADJUSTMENT CONDITIONS
OPERATION
VALUE
REFERENCE
FREQUENCY
(Band A)
[REF]
1 • Connect an RF power meter to the antenna
connector.
• Loosely couple a Frequency Counter to the
antenna connector.
• Transmitting
Rotate
Band B [DIAL]
to adjust
the transmit frequency, and then
touch
[ENT]
during transmit.
Displayed
frequency
(±200 Hz)
(Band B)
2
M
ENTERING THE ADJUSTMENT MODE
1) Connect the JIG cable to the
MICROPHONE CONNECTOR
(see the illustration on page 5-1).
2)
Turn
Band A [SQL]
maximum clockwise.
3)
Set
Band B [SQL]
to the center position.
4) Touch and hold
[QUICK]
, and turn ON the power.
• Enters to the adjustment mode.
MA
IN
B
A
N
D
Band A [DIAL]
Turn Clockwise : Selects the next adjustment item.
Turn Counterclockwise : Selects the previous adjustment item.
Band B [DIAL]
Adjusts the value for the item.
(For the manual adjustments)
Adjustment item name.
Adjustment value.
[ENT]
• Stores the set value.
(For the manual adjustments)
• Adjusts the value for the item.
(For the automatic adjustments)
Adjustment frequency.
4) Touch and hold
[QUICK]
, then push
[ ]
turn ON the power.
MA
IN
B
A
N
D
2) Turn
Band A [SQL]
maximum clockwise.
3) Set
Band B [SQL]
to the center position.
M
KEY ASSIGNMENTS IN THE ADJUSTMENT MODE
5-2 FREQUENCY ADJUSTMENT
1) Select the adjustment item by rotating
Band A [DIAL]
.
2) Set or modify the adjustment value as specifi ed by rotating
Band B [DIAL]
.
3) Touch
[ENT]
to store the value.