background image

ADJUSTMENT 

Adjustment          No.        Adjustment Condition & Tuning                      Value      Ref. No. CK. Point 

 

Checking TX S/N        Connect a linear detector via the attenuator 

                         to the antenna terminal, and set to the 

                         conditions below. 

                                              

      HPF          50 Hz 

                                                LPF          20 kHz 

                                                De-emphasis  OFF 

                                               Level Meter   (P/P)/2 

                                Apply a 1 kHz signal from the low frequency 

                                oscillator to the mic terminal, and  

                                transmit, then adjust the low frequency 

                                oscillator output level so that the maximum 

                                modulation is 70%.(WIDE:3.5KHz,NAR:1.75KHz) 

                                Check that the TX S/N in the bandwidth is 

                                as the values below. 

 

     WIDE            More than 40 dB              Over 40dB               ANT Con 

                                             NARROW           More than 34 dB              Over 34dB 

                  

Adjusting  RX

             

When there is no particular set limits, set 

Sensitivity              the RX adjustments and signal generator 

when checking to the settings below. 

 

                                        Modulation Freq.          1kHz 

                                                 WIDE                  ± 3.5 kHz 

                                               NARROW                 ± 1.75 kHz 

 

                                Set the signal generator in the following  

                                way for wide channels. 

               

                                        Adjust Freq.   Near Greatest Lo band F.        

                                       SG Input level           +20 dBu 

 

                                Connect an 4 ohm non-inductive load and                           Adj.Soft RSSI line  

                               a distortion meter to the external speaker 

                               terminal. Adjust BPF (T1) ~ (T2) with the 

                               adjustment software, so that the sensitivity  

                               is at maximum.              

 

 

                         

Summary of Contents for IC-F121S

Page 1: ...uring RX and C133 during TX Adj Freq 174 MHz RX Side 3 5V 3 5V C134 LV TX Side 3 5V 3 5V C133 Lock Voltage Set the transceiver to the 136 MHz Check and check that all is within specification Adj Freq...

Page 2: ...below Hi Power 40 0 60 0W 40 60W ANT Con L2 Power 20 0 30 0W 20 30W L1 Power 4 0 6 0W 4 0 6 0W Current Check at Check that the in band power consumption TX is within the specifications below Hi Power...

Page 3: ...nal Connect a millivolt meter or a 600 ohm out put impedance CR oscillator to the trans ceiver s mic terminal Modulation Use the adjustment software to adjust the Balance modulation analyzer s detecti...

Page 4: ...to the antenna terminal Set the transceiver to wide ch and CTCSS 151 4Hz Transmit while making sure no input is applied to the mic or mic terminal Adjust Freq Near Center Frequency Adj Soft ANT Con W...

Page 5: ...Hz Check that the TX S N in the bandwidth is as the values below WIDE More than 40 dB Over 40dB ANT Con NARROW More than 34 dB Over 34dB Adjusting RX When there is no particular set limits set Sensiti...

Page 6: ...center frequency Set the signal generator to the settings below ANT Con Modulation Freq 1kHz WIDE 3 5 kHz NARROW 1 75 kHz SG Output Level 16 5 dBu In this condition using the adjustment Adj Soft softw...

Page 7: ...e so that the AF output is 50 of the rated value Check that the RX S N in the bandwidth is as the values below WIDE More than 40 dB Over 40dB ANT Con NARROW More than 34 dB Over 34dB SP Jack Checking...