PSK decode set mode
This set mode is used to set the decode USOS func-
tion, time stamp setting, etc.
• Setting contents
q
During PSK mode operation, push [F-3•DECODE]
to select PSK decode screen.
w
Push [F-1•<MENU2>] to select PSK decode menu
2, then push [F-6•SET] to select PSK decode set
mode.
• Push [F-7•WIDE] to toggle the screen size from normal
and wide.
e
Push [F-1•
Y
] or [F-2•
Z
] to select the desired set
item.
r
Set the desired condition using the main dial.
• Push [F-4•DEF] for 1 sec. to select a default condition
or value.
• Push [F-3•
Ω ≈
] to select the set contents for some
items.
t
Push [EXIT/SET] to exit from set mode.
[F-1•
Y
]
Main dial
[EXIT/SET]
[F-2•
Z
] [F-4•DEF]
[F-3•
Ω ≈
] [F-7•WIDE]
4
RECEIVE AND TRANSMIT
Turn the time stamp (date, transmission or reception
time) display ON and OFF.
• ON
: Displays the time stamp.
• OFF : No time stamp display.
Selects the clock display for time stamp usage.
NOTE:
The time won’t be displayed when “OFF” is
selected in “PSK Time Stamp” as above.
• Local : Selects the time that set in “Time (Now).”
• UTC* : Selects the time that set in “CLOCK2.”
*The name of choice may differ according to
“CLOCK2 Name” setting (p, 11-2). “UTC” is the
default name of CLOCK2.
Set the FFT scope waveform averaging function from
2 to 4 and OFF. (default: OFF)
Recommendation!
If you use the FFT scope waveform for tuning, using
the default or smaller number setting is recom-
mended.
Set the color for the FFT scope waveform.
• The color is set in RGB format.
• The set color is indicated in the box beside the RGB scale.
• Push [F-3•
Ω ≈
] to select R (Red), G (Green) and B (Blue),
and then rotate the main dial to set the ratio from 0 to 255.
Select the AFC (Automatic Frequency Control) func-
tion operating range from ±15 Hz (default) and ±8 Hz.
NOTE:
The AFC function may not tune the signal
properly when a weak PSK signal is received.