background image

14-3

D

D

Command table

14

CONTROL COMMAND

Command

Sub command

Description

00

Send frequency data

01

Same as 

Send mode data

command 06

02

Read band edge frequencies

03

Read operating frequency

04

Read operating mode

05

Set operating frequency 

06

00

Select LSB

01

Select USB

02

Select AM

03

Select CW

04

Select RTTY

05

Select FM

07

Select CW-R

08

Select RTTY-R

12

Select PSK

13

Select PSK-R

07

Select VFO mode

B0

Exchange main and sub bands

B1

Equalize main and sub bands

C0

Turn the dualwatch OFF

C1

Turn the dualwatch ON

D0

Select main band

D1

Select sub band

08

Select memory mode

0001–0101*

Select memory channel
*P1=0100, P2=0101

09

Memory write

0A

Memory to VFO

0B

Memory clear

0E

00

Scan stop

01

Programmed/memory scan start

02

Programmed scan start

03

F scan start

12

Fine programmed scan start

13

Fine 

F scan start

22

Memory scan start

23

Select memory scan start

A1–A7

Set 

F scan span (A1=±5 kHz;

A2=±10 kHz; A3=±20 kHz;
A4=±50 kHz; A5=±100 kHz; 
A6=±500 kHz; A7=±1 MHz)

B0

Set as non-select channel

B1

Set as select channel (1=

1;

2=

2; 3=

3; when no data com-

mand is specified, the previously
set number or “

1” is selected)

B2

Set the number for select memory
scan (0=ALL; 1=

1; 2=

2; 3=

3)

D0

Set scan resume OFF

D3

Set scan resume ON

0F

00

Turn the split function OFF

01

Turn the split function ON

10

00

Select 10 Hz (1 Hz) tuning step

01

Select 100 Hz tuning step

02

Select 1 kHz tuning step

03

Select 5 kHz tuning step

04

Select 9 kHz tuning step

05

Select 10 kHz tuning step

06

Select 12.5 kHz tuning step

07

Select 20 kHz tuning step

08

Select 25 kHz tuning step

Command

Sub command

Description

11

Select/read attenuator (0=OFF;
1=3 dB; 2=6 dB; 3=9 dB; 4=12 dB;
5=15 dB; 6=18 dB; 7=21 dB)

12

00 + RX ANT

Select/read ANT1 selection
(00=RX ANT OFF; 01=RX ANT ON)

01 + RX ANT

Select/read ANT2 selection
(00=RX ANT OFF; 01=RX ANT ON)

02 + RX ANT

Select/read ANT3 selection
(00=RX ANT OFF; 01=RX ANT ON)

03 + RX ANT

Select/read ANT4 selection
(00=RX ANT OFF; 01=RX ANT ON)

13

00

Announce with voice synthesizer

01

(00=all data; 01=frequency and 

02

S-meter level; 02=receive mode)

14

01 + Level data

[AF] level setting (0=max. CCW to
255=max. CW)

02 + Level data

[RF] level setting (0=max. CCW to
255=11 o’clock)

03 + Level data

[SQL] level setting (0=11 o’clock to
255=max. CW)

05 + Level data

[APF] level setting
(0=Pitch–550 Hz, 128=Pitch,
255=Pitch+550 Hz; 10 Hz steps)

06 + Level data

[NR] level setting (0=min. to
255=max.)

07 + Level data

Inside [TWIN PBT] setting or IF
shift setting (0=max. CCW,
128=center, 255=max. CW)

08 + Level data

Outside [TWIN PBT] setting 
(0=max. CCW, 128=center,

255=max. CW)

09 + Level data

[CW PITCH] setting (0=300 Hz,
128=600 Hz, 255=900 Hz; 5 Hz
steps)

0A + Level data

[RF POWER] setting (0=max.
CCW to 255=max. CW)

0B + Level data [MIC] setting (0=max. CCW to

255=max. CW)

0C + Level data [KEY SPEED] setting (0=max.

CCW to 255=max. CW)

0D + Level data [NOTCH] setting (0=low freq. to

255=high freq.)

0E + Level data [COMP] setting (0=max. CCW to

255=max. CW)

0F + Level data

[DELAY] setting (0=max. CCW to
255=max. CW)

11 + Level data

[AGC] control setting (0=max.
CCW to 255=max. CW)

12 + Level data

[NB] control setting (0=max. CCW
to 255=max. CW)

13 + Level data

[DIGI-SEL] setting (0=max. CCW
to 255=max. CW)

14 + Level data

[DRIVE] setting (0=max. CCW to
255=max. CW)

15 + Level data

[MONI GAIN] setting (0=max.
CCW to 255=max. CW)

16 + Level data

[VOX GAIN] setting (0=max.
CCW to 255=max. CW)

17 + Level data

[ANTI VOX] setting (0=max. CCW
to 255=max. CW)

18 + Level data

[CONTRAST] setting (0=max.
CCW to 255=max. CW)

19 + Level data

[BRIGHT] setting (0=max. CCW
to 255=max. CW)

Summary of Contents for IC-7800

Page 1: ...T several times returns to the start up screen See p 12 3 for set mode arrangement 1 PANEL DESCRIPTION Spectrum scope screen p 5 2 Voice recorder screen p 7 3 RTTY decoder screen p 4 13 Memory keyer s...

Page 2: ...D D CW side tone function When the transceiver is in the receive condition and the break in function is OFF p 6 3 you can listen to the CW side tone without actually transmitting This allows you to m...

Page 3: ...F12 on the connected keyboard to transmit TX indicator lights red y Type from the keyboard to enter the contents that you want to transmit The typewritten contents are indicated in the TX buffer scree...

Page 4: ...type during wide screen indication can be selected in display set mode pgs 3 11 12 11 u Push F 6 MAIN SUB to toggle the MAIN and SUB band for decode operation Dualwatch function p 5 16 should be ON wh...

Page 5: ...er code decoding after receiving a space USOS UnShift On Space function capability ON and OFF ON Decode as letter code OFF Decode as character code Selects the new line code of the internal RTTY de co...

Page 6: ...ed in the box beside the RGB scale Push F 3 to select R Red G Green and B Blue and then rotate the main dial to set the ratio from 0 to 255 Selects the operating frequency indication for time stamp us...

Page 7: ...nal is received t Press F12 of the connected keyboard to transmit TX indicator lights red y Type from the connected keyboard to enter the message that you want to transmit The typewritten contents are...

Page 8: ...NET function ON appears additionally i Push F 3 AFC NET for 1 sec to add the offset fre quency to the displayed frequency o Push F 7 WIDE to toggle the PSK decode screen size from normal and wide S R...

Page 9: ...e stamp OFF No time stamp display Selects the clock display for time stamp usage NOTE The time won t be displayed when OFF is selected in PSK Time Stamp as above Local Selects the time that set in Tim...

Page 10: ...5 Set the text color for transmitted characters The color is set in RGB format The set color is indicated in the box beside the RGB scale Push F 3 to select R Red G Green and B Blue and then rotate th...

Page 11: ...ET MODE D D Screen arrangement Set mode menu screen p 12 2 Level set mode p 12 4 ACC set mode p 12 6 Time set mode p 11 2 Display set mode p 12 11 Miscellaneous Others set mode p 12 14 CF card set men...

Page 12: ...f frequen cies Lower freq 100 200 300 default and 500 Hz Higher freq 2500 2700 default 2800 and 2900 Hz Sets the transmission passband width to narrow set ting by changing the lower and higher cut off...

Page 13: ...IC 780 3 and IC 780 4 default Italic 1 Selects the desired font for the displays other than fre quency readout from Normal and Slim default Normal Display set mode Selects the desired S RF meter type...

Page 14: ...bility ON and OFF default ON Sets the memory name indication during memory mode operation ON and OFF default ON ON The programmed memory name is displayed above the frequency indication OFF No memory...

Page 15: ...ailable in the IC 7800 q Push EXIT SET several times to close multi func tion screen if necessary w Push F 7 SET to select set mode menu screen e Push F 3 DISP to enter display set mode r Push F 1 Y o...

Page 16: ...enuator 0 OFF 1 3 dB 2 6 dB 3 9 dB 4 12 dB 5 15 dB 6 18 dB 7 21 dB 12 00 RX ANT Select read ANT1 selection 00 RX ANT OFF 01 RX ANT ON 01 RX ANT Select read ANT2 selection 00 RX ANT OFF 01 RX ANT ON 02...

Page 17: ...0 for details 050162 Send read time stamp text font color see p 14 10 for details 050163 Send read text font color in TX buffer see p 14 10 for details Command Sub command Description 1A 050164 Send r...

Page 18: ...4 Set read PSK AFC function tuning range 0 8 Hz 1 15 Hz 06 Send read DATA mode with filter set see p 14 10 for detail 07 Send read SSB transmit band width 0 WIDE 1 MID 2 NAR 08 Send read DSP filter sh...

Page 19: ...0 ANT1 1 ANT2 2 ANT3 3 ANT4 4 TX ANT1 RX ANT4 5 TX ANT2 RX ANT4 6 TX ANT3 RX ANT4 RX should be selected for ANT4 q X X X X w 00 Data mode OFF 01 FIL1 02 FIL2 03 FIL3 00 Data mode OFF 01 Data mode 1 D...