53
8
SET MODE
■
Set mode description
Set mode is used for programming infrequently
changed values or conditions of functions. This trans-
ceiver has a level set mode, display set mode, timer
set mode and miscellaneous (others) set mode.
• Set mode operation
q
If the start up screen is not selected (if [F-5]’s func-
tion is [EXIT]), push [F-5] one or more times to exit.
w
Push [
(F-5)
SET] to select the set mode screen.
e
Push [
(F-1)
LEVEL], [
(F-2)
DISP], [
(F-3)
TIME] or
[
(F-4)
OTHERS] to enter the desired set mode.
r
Push [
(F-1)
Y
] or [
(F-2)
Z
] to select the desired item.
t
Set the desired condition using the tuning dial.
- Push [
(F-3)
DEF] to select a default condition or value.
y
For timer set mode, push [
(F-4)
SET] to enter the set
time.
u
Push [
(F-5)
EXIT] twice to exit the set mode.
1ß
14.195.00
VFO
VFO
USB
USB
USB
USB
14.100.00
14.100.00
1ß 14.100.00
14.100.00
14.205.00
14.205.00
USB
USB
USB
USB
T X
VOX
VOX
OFF
OFF
COMP
COMP
OFF
OFF
ANT
ANT
1
METER
METER
Po
Po
P.AMP
P.AMP
OFF
OFF
ATT
ATT
OFF
OFF
AGC
AGC
MID
MID
2.4k
2.4k
9
2.8k
2.8k
455
455
12:34
12:34
VFO
VFO
L E V E L
D I S P L A Y
T I M E & T I M E R
O T H E R S
[SET
[SET MODE]
MODE]
DISP
DISP
OTHERS
OTHERS
TIME
TIME
EXIT
EXIT
LEVEL
LEVEL
[TIMER SET]
[TIMER SET]
≥
≥
VOX
VOX
ON
ON
COMP
COMP
OFF
OFF
≤
≤
AGC
AGC
MID
MID
EXIT
EXIT
0 : 0 0
6 0 m i n
P o w e r - O N t i m e r s e t
P o w e r - O F F p e r i o d
1 2 : 3 4
T i m e ( n o w )
≥
≥
DEF
DEF
VOX
VOX
OFF
OFF
COMP
COMP
OFF
OFF
≤
≤
AGC
AGC
MID
MID
[LEVEL SET]
[LEVEL SET]
EXIT
EXIT
T X t o n e ( B a s s )
0 d B
0 d B
5 0 %
T X t o n e ( T r e b l e )
B e e p
M o n i t o r
5 0 %
≥
≥
DEF
DEF
VOX
VOX
OFF
OFF
COMP
COMP
OFF
OFF
≤
≤
AGC
AGC
MID
MID
[DISPLAY SET]
[DISPLAY SET]
EXIT
EXIT
C o n t r a s t ( L C D )
5 0 %
5 0 %
8
B a c k l i g h t ( L C D )
B a c k l i g h t ( s w i t c h e s )
F-1
F-2
F-3
F-5
F-4
•Level set mode (p. 54)
•Start up screen
•Set mode screen
•Display set mode (p. 54)
•Timer set mode (pgs. 51, 55)
AGC
AGC
MID
MID
•Miscellaneous (others) set mode (p. 55)
≥
≥
DEF
DEF
VOX
VOX
OFF
OFF
COMP
COMP
OFF
OFF
≤
≤
[OTHERS SET]
[OTHERS SET]
EXIT
EXIT
C a l i b r a t i o n m a r k e r
O F F
N O N E
N O N E
O N
O N
H I G H
O N
R F + S Q L
O N
F i l t e r ( 9 M H z )
F i l t e r ( 4 5 5 k H z )
B e e p ( c o n f i r m a t i o n )
B e e p ( b a n d e d g e )
S c a n s p e e d
S c a n r e s u m e
R F / S Q L c o n t r o l
Q u i c k d u a l w a t c h
1ß
14.195.00
VFO
VFO
USB
USB
USB
USB
14.100.00
14.100.00
1ß 14.100.00
14.100.00
14.205.00
14.205.00
USB
USB
USB
USB
T X
FILTER
FILTER
SCAN
SCAN
MEMORY
MEMORY
SET
SET
VOX
VOX
OFF
OFF
COMP
COMP
OFF
OFF
SCOPE
SCOPE
ANT
ANT
1
METER
METER
Po
Po
P.AMP
P.AMP
OFF
OFF
ATT
ATT
OFF
OFF
AGC
AGC
MID
MID
2.4k
2.4k
9
2.8k
2.8k
455
455
12:34
12:34
VFO
VFO