49
6
SCANS
Fine scan functions as programmed or
∂
F scan, but
scan speed decreases when the squelch opens and
does not stop. The scanning tuning step shifts from
50 Hz to 10 Hz while the squelch opens.
q
Select the scan screen from the start up screen by
pushing [
(F-4)
SCAN].
w
Set for programmed scan or
∂
F scan as described
on previous page.
e
Push [
(F-1)
PROG] or [
(F-2)
∂
F] to start a scan.
- Decimal points blink while scanning.
r
Push [
(F-3)
FINE] to start a fine scan.
- “FINE PROGRAM SCAN” or “FINE
∂
F SCAN” ap-
pears.
t
When the scan detects a signal, the scan speed
decreases but does not stop.
y
Push [
(F-1)
PROG] or [
(F-2)
∂
F] to stop the scan;
push [
(F-3)
FINE] to cancel the fine scan.
■
Fine programmed scan/fine
∂
∂
F scan
2.4k
2.4k
9
2.8k
2.8k
455
455
12:34
12:34
P r o g r a m m e d P 1 : 0 . 5 0 0 . 0 0 M H z
S c a n e d g e s P 2 : 2 9 . 9 9 9 . 9 9 M H z
∂ F S p a n : ± 1 0 k H z
[SCAN]
[SCAN]
∂F
∂FSPAN
FSPAN
FINE
FINE
EXIT
EXIT
PROG
PROG
VOX
VOX
OFF
OFF
COMP
COMP
OFF
OFF
ANT
ANT
1
METER
METER
Po
Po
P.AMP
P.AMP
OFF
OFF
ATT
ATT
OFF
OFF
AGC
AGC
MID
MID
P R O G R A M S C A N
1ß
14.195.00
VFO
VFO
USB
USB
USB
USB
14.100.00
14.100.00
1ß 14.100.00
14.100.00
14.205.00
14.205.00
USB
USB
USB
USB
T X
VFO
VFO
2.4k
2.4k
9
2.8k
2.8k
455
455
12:34
12:34
P r o g r a m m e d P 1 : 0 . 5 0 0 . 0 0 M H z
S c a n e d g e s P 2 : 2 9 . 9 9 9 . 9 9 M H z
∂ F S p a n : ± 1 0 k H z
[SCAN]
[SCAN]
∂F
∂FSPAN
FSPAN
FINE
FINE
EXIT
EXIT
PROG
PROG
VOX
VOX
OFF
OFF
COMP
COMP
OFF
OFF
ANT
ANT
1
METER
METER
Po
Po
P.AMP
P.AMP
OFF
OFF
ATT
ATT
OFF
OFF
AGC
AGC
MID
MID
F I N E P R O G R A M S C A N
1ß
14.195.00
VFO
VFO
USB
USB
USB
USB
14.100.00
14.100.00
1ß 14.100.00
14.100.00
14.205.00
14.205.00
USB
USB
USB
USB
T X
VFO
VFO
q
If the start up screen is not selected (if [F-5]’s func-
tion is [EXIT]), push [F-5] one or more times to exit.
w
Select memory mode.
e
Select the desired operating mode.
- The operating mode can also be changed while scan-
ning.
r
Push [
(F-4)
SCAN] to select the scan screen.
t
Set [RF/SQL] open or closed.
- See p. 47 for scan condition.
- If the [RF/SQL] control function is set as RF control, the
squelch always opens. See pgs. 2, 56 for details.
y
Push [
(F-1)
MEMORY] to start the memory scan.
- Decimal points blink while scanning.
u
When the scan detects a signal, the scan stops,
pauses or ignores it depending on the resume set-
ting and the squelch condition.
i
To cancel the scan, push [
(F-1)
MEMORY].
NOTE: 2 or more memory channels must be pro-
grammed for memory scan to start.
■
Memory scan operation
2.4k
2.4k
9
2.8k
2.8k
455
455
12:34
12:34
P r o g r a m m e d P 1 : 0 . 5 0 0 . 0 0 M H z
S c a n e d g e s P 2 : 2 9 . 9 9 9 . 9 9 M H z
∂ F S p a n : ± 1 0 k H z
[SCAN]
[SCAN]
∂F
∂FSPAN
FSPAN
SELECT
SELECT
EXIT
EXIT
MEMORY
MEMORY
VOX
VOX
OFF
OFF
COMP
COMP
OFF
OFF
ANT
ANT
1
METER
METER
Po
Po
P.AMP
P.AMP
OFF
OFF
ATT
ATT
OFF
OFF
AGC
AGC
MID
MID
VFO
VFO
14.195.00
USB
USB
USB
USB
14.100.00
14.100.00
1ß 14.100.00
14.100.00
14.205.00
14.205.00
USB
USB
USB
USB
T X
VFO
VFO
12
12
MEMORY
MEMORY
2.4k
2.4k
9
2.8k
2.8k
455
455
12:34
12:34
P r o g r a m m e d P 1 : 0 . 5 0 0 . 0 0 M H z
S c a n e d g e s P 2 : 2 9 . 9 9 9 . 9 9 M H z
∂ F S p a n : ± 1 0 k H z
[SCAN]
[SCAN]
∂F
∂FSPAN
FSPAN
SELECT
SELECT
EXIT
EXIT
VOX
VOX
OFF
OFF
COMP
COMP
OFF
OFF
ANT
ANT
1
METER
METER
Po
Po
P.AMP
P.AMP
OFF
OFF
ATT
ATT
OFF
OFF
AGC
AGC
MID
MID
M E M O R Y S C A N
14.195.00
USB
USB
USB
USB
14.100.00
14.100.00
1ß 14.100.00
14.100.00
14.205.00
14.205.00
USB
USB
USB
USB
T X
VFO
VFO
VFO
VFO
12
12