19
CONTROL COMMAND
19-3
Remote control (CI-V) information (Continued)
Cmd. Sub cmd.
Data
Description
00
p. 19-8
Send frequency data (transceive)
01
p. 19-8
Send mode data (transceive)
02
p. 19-8
Read band edge frequencies
03
p. 19-8
Read operating frequency
04
p. 19-8
Read operating mode
05
p. 19-8
Set operating frequency
06
p. 19-8
Operating mode selection for transceive
07
Select the VFO mode
00
Select VFO A
01
Select VFO B
A0
Equalize VFO A and VFO B
B0
Exchange VFO A and VFO B
08
Select the Memory mode
0001 to
0109
Select the Memory channel
*(0001=M-CH01, 0099=M-CH99)
0100
Select program scan edge channel P1
0101
Select program scan edge channel P2
09
Memory write
0A
Memory copy to VFO
0B
Memory clear
0E 00
Scan stop
01
Programmed/memory scan start
02
Programmed scan start
03
F scan start
12
Fine programmed scan start
13
Fine
∂
F scan start
22
Memory scan start
23
Select memory scan start
A1
Select
∂
F scan span ±5 kHz
A2
Select
∂
F scan span ±10 kHz
A3
Select
∂
F scan span ±20 kHz
A4
Select
∂
F scan span ±50 kHz
A5
Select
∂
F scan span ±100 kHz
A6
Select
∂
F scan span ±500 kHz
A7
Select
∂
F scan span ±1 MHz
B0
Set as non-select channel
B1
Set as select channel
( The previously set number by CI-V is set
after turning power ON, or “1” is selected if
no selection is performed.)
01 to 03 Set as select channel
*(01=SEL1, 02=SEL2, 03=SEL3)
B2
00 to 03 Set for select memory scan
*(00=ALL, 01=SEL1, 02=SEL2, 03=SEL3)
D0
Set Scan resume OFF
D3
Set Scan resume ON
0F
00/01
Read Split setting (00=OFF, 01=ON)
00
Turn the split function OFF
01
Turn the split function ON
10*
00
Send/read the tuning step OFF
01
Send/read the 100 Hz tuning step
02
Send/read the 1 kHz tuning step
03
Send/read the 5 kHz tuning step
04
Send/read the 9 kHz tuning step
05
Send/read the 10 kHz tuning step
06
Send/read the 12.5 kHz tuning step
07
Send/read the 20 kHz tuning step
08
Send/read the 25 kHz tuning step
11*
00/20
Send/read Attenuator
*(00=OFF, 20=20dB ON)
13 00
Speech all data with voice synthesizer
01
Speech the operating frequency and S meter
level by voice synthesizer
02
Speech the operating mode by voice
synthesizer
14* 01
0000 to
0255
Send/read the AF level
*(0000=min. to 0255=max.)
02
0000 to
0255
Send/read the RF gain level
*(0000=min. to 0255=max.)
03
0000 to
0255
Send/read the squelch level
*(0000=min. to 0255=max.)
Cmd. Sub cmd.
Data
Description
06
0000 to
0255
Send/read the NR level
*(0000=0% to 0255=100%)
07
0000 to
0255
Send/read inner [TWIN PBT] position
*( 0000=max. CCW, 0128=center, 0255=max.
CW)
08
0000 to
0255
Send/read outer [TWIN PBT] position
*( 0000=max. CCW, 0128=center, 0255=max.
CW)
09
0000 to
0255
Send/read CW pitch
*( 0000=300 Hz, 0128=600 Hz, 0255=900 Hz;
5 Hz steps)
0A
0000 to
0255
Send/read [RF PWR] position
*(0000=max. CCW, 0255=max. CW)
0B
0000 to
0255
Send/read [MIC] position
*(0000=max. CCW, 0255=max. CW)
0C
0000 to
0255
Send/read [KEY SPEED] level
*(0000=6wpm, 0255=48wpm)
0D
0000 to
0255
Send/read [NOTCH] position
*( 0000=max. CCW, 0128=center, 0255=max.
CW)
0E
0000 to
0255
Send/read the COMP level
*(0000=0 to 0255=10)
0F
0000 to
0255
Send/read the Break-IN Delay setting
*(0000=2.0d to 0255=13.0d)
12
0000 to
0255
Send/read NB level
*(0000=0% to 0255=100%)
15
0000 to
0255
Send/read the Monitor gain
*(0000=0% to 0255=100%)
16
0000 to
0255
Send/read the VOX gain
*(0000=0% to 0255=100%)
17
0000 to
0255
Send/read the Anti VOX gain
*(0000=0% to 0255=100%)
19
0000 to
0255
Send/read BRIGHT level
*(0000=0%, 0255=100%)
15 01
00/01
Read noise or S-meter squelch status
*(squelch close)
02
0000 to
0255
Read S-meter level
*(0000=S0, 0120=S9, 0241=S9+60dB)
05
00/01
Read various squelch function’s status
*(squelch closed)
07
00/01
Read the OVF icon status
(00=Disappears, 01=Appears)
11
0000 to
0255
Read PO meter level
*(0000=0%, 0143=50%, 213=100%)
12
0000 to
0255
Read SWR meter level
*( 0000=SWR1.0, 0048=SWR1.5,
0080=SWR2.0, 0120=SWR3.0)
13
0000 to
0255
Read ALC meter level
*(0000=Min. to 0120=Max.)
14
0000 to
0255
Read COMP meter level
*(0000=0 dB, 0130=15 dB,0241=30 dB)
15
0000 to
0255
Read Vd meter level
*(0000=0 V, 0013=10 V, 0241=16 V)
16
0000 to
0255
Read Id meter level
*(0000=0, 0097=10, 0146=15, 0241=25)
16* 02
00 to 02 Preamp
( 00=OFF, 01=Preamp 1 ON, 02=Preamp 2 ON)
12
00 to 03 AGC
*(00=OFF, 01= FAST, 02= MID, 03=SLOW)
22
00 to 01 Noise blanker *(00=OFF, 01=ON)
40
00 to 01 Noise reduction *(00=OFF, 01=ON)
41
00 to 01 Auto notch function *(00=OFF, 01=ON)
42
00 to 01 Repeater tone *(00=OFF, 01=ON)
43
00 to 01 Tone squelch *(00=OFF, 01=ON)
44
00 to 01 Speech compressor *(00=OFF, 01=ON)
45
00 to 01 Monitor function *(00=OFF, 01=ON)
46
00 to 01 VOX function *(00=OFF, 01=ON)
47
00 to 02 BK-IN function
*( 00=BK-IN OFF, 01=Semi BK-IN ON,
02=Full BK-IN ON)
48
00 to 01 Manual notch function *(00=OFF, 01=ON)
D
Command table
Previous view