background image

4-1

 

SECTION 4  

ADJUSTMENT PROCEDURE

4-1 PREPARATION

M

 

REQUIRED EQUIPMENTS

GENERAL CONNECTION

• Front panel

• Rear panel

EQUIPMENT

GRADE AND RANGE

EQUIPMENT

GRADE AND RANGE

Shunt plug

Modified 3.5 mm (1/8 inch) monaural plug 
(See the illustration below.)

Dummy Loads

Impedance:  

50 

 and 100 

/120 W

Attenuator

Attenuation:  

50 dB/120 W

RF power meter
(50 

Ω 

terminated)

Measuring range: 

 1–120 W

Frequency range: 

 0.1–60 MHz

SWR: 

 Less than 1.2 : 1

Standard signal 
generator (SSG)

Frequency range:  0.1–60 MHz
Output level: 

 –20 dBµ to +94 dBµ

 

 (–127 to –13 dBm)

Frequency counter

Frequency range: 

 0.1–60 MHz

Frequency  accuracy:   ±1 ppm or better
Input level: 

 Less than 1 mW

Audio generator
(AG)

Frequency range:  300–3000 Hz
Output level: 

 1–500 mV

AC Millivoltmeter

Measuring range:  10 mV to 10 V

[SP]

[REMOTE]

[ANT]

<Rear view>

<Front view>

AC MILLIVOLT METER

(10 mV to 10 V)

EXT. SPEAKER

(2 W/8 

Ω)

+

+

DUMMY LOAD

(50 or 100 

/120 W)

RF POWER METER

(120 W/50 

Ω)

STANDARD SIGNAL GENERATOR

(0.1–60 MHz)

NEVER TRANSMIT

 while the SSG is connected.

FREQUENCY COUNTER

(0.1–60 MHz)

ATTENUATOR

(50 dB/120 W)

[DC 13.8V]

Fuses

25 A

DC power supply

(13.8 V/30 A)

Black

Red

Supplied DC cable

[MIC]

Audio

generator

PTT

[MIC]

AC millivolt-

meter

MIC

PTT

MICE

GENERAL CONNECTION

(Short)

• Short plug
 

(For entering the adjustment mode)

3.5 mm (1/8 inch) monaural plug

(Shunt)

14.150.00

USB

TX

ADJUST MODE

FIL2

FRONT Preset

TX/ID

RX

TUNER/REF

Sub adjustment menu

<Main adjustment menu screen >

14.150.00

USB

TX

ADJUST MODE

== RX ==

FIL2

Gain

S Meter

Rotate to adjust

Push to exit the menu

Sub adjustment menu

Adjustment item

<Sub adjustment menu screen example>

[SP]

[REMOTE]

[ANT]

<Rear view>

<Front view>

AC MILLIVOLT METER

(10 mV to 10 V)

EXT. SPEAKER

(2 W/8 

Ω)

+

+

DUMMY LOAD

(50 or 100 

/120 W)

RF POWER METER

(120 W/50 

Ω)

STANDARD SIGNAL GENERATOR

(0.1–60 MHz)

NEVER TRANSMIT

 while the SSG is connected.

FREQUENCY COUNTER

(0.1–60 MHz)

ATTENUATOR

(50 dB/120 W)

[DC 13.8V]

Fuses

25 A

DC power supply

(13.8 V/30 A)

Black

Red

Supplied DC cable

[MIC]

Audio

generator

PTT

[MIC]

AC millivolt-

meter

MIC

PTT

MICE

GENERAL CONNECTION

(Short)

• Short plug
 

(For entering the adjustment mode)

3.5 mm (1/8 inch) monaural plug

(Shunt)

14.150.00

USB

TX

ADJUST MODE

FIL2

FRONT Preset

TX/ID

RX

TUNER/REF

Sub adjustment menu

<Main adjustment menu screen >

14.150.00

USB

TX

ADJUST MODE

== RX ==

FIL2

Gain

S Meter

Rotate to adjust

Push to exit the menu

Sub adjustment menu

Adjustment item

<Sub adjustment menu screen example>

Reviews: