8
SET MODE
47
• CI-V address
To distinguish equipment, each CI-V transceiver has its own
Icom standard address in hexadecimal code. The IC-718’s
address is 5E.
When 2 or more IC-718s are connected to an optional CT-
17 CI-V
LEVEL CONVERTER
, rotate the main dial to select a
different address for each IC-718 in the range 01H to 7FH.
The default is 5E.
• CI-V Transceive
Transceive operation is possible with the IC-718 connected
to other Icom HF transceivers or receivers. When “on”is se-
lected, changing the frequency, operating mode, etc. on the
IC-718 automatically changes those of connected trans-
ceivers (or receivers) and vice versa.
The default is on.
• CI-V 731 mode
When connecting the IC-718 to the IC-735 for transceive
operation, you must change the operating frequency data
to 4 bytes.
• This item MUST be set to “on” when operating transceiver with
the IC-735.
The default is oF (off).
• OPTION Filter
When an optional IF filer is installed, this selection is nec-
essary, otherwise the filters cannot be selected. Selections
available are FL-96, FL-222, FL-52A, FL-53A, FL-257 and
none (default). See p. 24 for usable filters for each mode
and see P. 50 for filter installation.
• Expand Filter
When an optional IF filter is installed, this selection expands
filter and filter selection (W/N) key combination on operating
mode independently.
The default is oF (off).
• Filter select (Wide/Narrow)
When an optional IF filter is installed, you can arrange the
filter and filter selection key combination. (p. 25)