42
7
SCAN OPERATION
7
■
Scan resume condition
The scan resume condition can be selected as timer or pause
scan. The selected resume condition is also used for priority
watch. (p. 44)
q
Push
[SET
]
to enter set mode.
w
Push
[SET]
or
[MONI]
several times until “SCT” or “SCP”
appears as shown above.
• When “d” is displayed in place of the 100 MHz digit, cancel the
DTMF memory encoder in advance. (p. 46)
e
Rotate
[DIAL]
to set the desired timer:
• “SCT-15”
: Scan pauses 15 sec. while receiving a signal.
• “SCT-10”
: Scan pauses 10 sec. while receiving a signal.
• “SCT-5”
: Scan pauses 5 sec. while receiving a signal.
• “SCP-2”
: Scan pauses until the signal disappears and then
resumes 2 sec. later.
r
Push any keys than
[SET]
or
[MONI]
to exit set mode.
z
Push
[
SET
B(D-OFF)]
to enter set mode.
x
Push
[
SET
B(D-OFF)]
or
[
ENT
C(T-OFF)]
several
times until “SCT” or “SCP” appears as shown at
left.
c
Push
[
Y
Y
]
or
[
Z
Z
]
to select the scan resume condi-
tion.
• See item
e
at left for scan resume condition details.
v
Push
[
CLR
A(MW)]
to exit set mode.
NOTE:
Set mode cannot be accessed when memory names are
displayed. To set the scan resume condition, return to fre-
quency indication by pushing
[MONI
]
on the front
panel for 1 sec., or push
[FUNC]
then
[
MONI
1(ANM)]
(HM-
133V) to cancel the channel name indication, then set as
described on this page.
ANM
SET
B
USING
SET MODE
LOCK
LOCK
SET
ANM
MONI
DUP
LOW
T-SCAN
TONE
PRIO
M/CALL
SCAN
V/ MHz
DIGITAL PRIO AO BUSY
MUTE
NAR
MID
LOW
The display shows that
the scan will resume
15 sec. after it stops.