Make  sure  the  AC  [POWER]  switch  is  turned 
OFF  when  connecting  an  AC  power  cable  or  a 
backup battery (emergency power supply).

The CY FR series can operate with either an AC 
or DC input. If AC power is interrupted and there 
is  an  external  DC  source  (emergency  power 
supply),  the  Repeater  will  continue  to  operate 
until the DC source is exhausted.

NOTE:

  IF  turning  the  Repeater  OFF  using 

the  rear  panel  switch,  wait  a  few  seconds 
before  turning  it  back  ON.  Otherwise,  Logic 
circuits  may  not  sense  the  transition.  The 
AC  Power  switch  does  not  effect  the  DC 
supply.  If  Repeater  is  operating  on  DC,  you 
must  use  the  power  switch(s)  on  the  Radio.

 

In AC operation

• Use the supplied AC power cable for    

 

  connection to a domestic AC outlet.
• Extension cords should not be used unless    
  absolutely necessary. Using improper   
  extension cords could result in fire risk.
• An International AC power cable is available.    
  The internal AC power supply is jumper    

 

  selectable between 120V

ac

 and 220V

ac

 .

 

In DC operation

CAUTION: 

Voltages greater than 16 VDC    

will damage the repeater. Check the source   
voltage before connecting the power cable.

•  DO NOT place the backup battery on or near  
  the repeater. Lead-acid batteries should be    
  placed at least 5 m (16.4 ft.) away from the    
  repeater. Use a heavy duty cable to make  

 

  the connection and be sure both the positive   
(red) and negative (black) terminals are   

 

correctly connected.
•  When connecting to the battery, connect  

 

  the   DC power cable to the repeater first, then  
  the positive (red) terminal and negative  

 

  (black) terminal to the battery. This is  to  

 

  prevent an electric shock or circuit damage.

■ 

Power

     

          INSTALLATION AND CONNECTIONS    2 

 

            

6

• Remove jumper for 220V operation.
• Install jumper for 120V operation.  

 

WARNING

DANGER OF ELECTRIC 

SHOCK.

 Disconnect AC power before 

changing voltage select jumper. 

 

120V/220V Jumper

(-) Negative (black)

(+) Positive (red)

Summary of Contents for CY 6000

Page 1: ...INSTRUCTION MANUAL VHF FM REPEATER CY 5000 UHF FM REPEATER CY 6000...

Page 2: ...nal part or connectors on the rear panel of the repeater This may result in an electric shock NEVER expose the repeater to rain snow or any liquids AVOID using or placing the repeater in areas with te...

Page 3: ...ration FEATURES Automatic battery backup and charging system A built in backup system supports automatic switching to an external battery 13 6 V DC if the AC power supply fails Other features PC progr...

Page 4: ...modular jack accepts the optional Field Service Aid 1 PANEL DESCRIPTION Front Panel 1 8 V DC output Max 15 mA Output port for PC programming AFO M PTT Input port for TX control Microphone ground Micro...

Page 5: ...nnector AC POWER SOCKET AC Connects the supplied AC power cable to a 120V or 220V AC outlet 120V or 220V internal jumper selectable GROUND TERMINAL GND Ground the repeater through this terminal to pre...

Page 6: ...Active L 16 EXT I O 16 The desired function can be assigned Default P0 Monitor Output 5 V pull up Active L 17 EXT I O 17 The desired function can be assigned Default Busy Output 5 V pull up Active L...

Page 7: ...your local dealer for more information and recommendations Duplexer A duplexer is separately required when only one antenna is used for both transmitting and receiving Select a duplexer according to...

Page 8: ...th following current capacity Solder or clamp the cable plug when connecting the power cable to the backup battery to prevent voltage drops Power cable current capacity 25 A or more TX TX RX ANT RX AN...

Page 9: ...ould result in fire risk An International AC power cable is available The internal AC power supply is jumper selectable between 120Vac and 220Vac In DC operation CAUTION Voltages greater than 16 VDC w...

Page 10: ...is installed or adjust the internal units etc CAUTION Disconnect the AC power cable and or DC power cable from the repeater Otherwise there is danger of electric shock and or equipment damage Remove...

Page 11: ...ed from the speaker Transmitting for Local Control Take the microphone off hook Wait for the channel to become clear Push and hold PTT to transmit then speak into the microphone at your normal voice l...

Page 12: ...the repeater stops functioning try to find the source of the problem and replace the damaged fuse with a new rated fuse 9 CAUTION DISCONNECT the DC power cable from the repeater Otherwise there is a...

Page 13: ...5 250 VAC 50 60 hz 13 6 VDC nominal 16 2 Amp Max Dimensions Projections 480 W x 133 H x 364 D mm not included 18 90 W x 524 H x 14 33 D in Weight 8 6 kg 18 lb 10 Optional Duplexer and Preselector spec...

Page 14: ...E HM 152T DTMF MICROPHONE Hand microphone with a DTMF keypad SM 25 DESKTOP MICROPHONE SP 22 SPEAKER IAS VHF DUP KIT VHF duplexer kit with RF jumpers IAS UHF DUP KIT UHF duplexer kit with RF jumpers 22...

Page 15: ...MEMO...

Page 16: ...009 Icom America Inc The Icom logo is a registered trademark of Icom Inc All specifications and information is subject to change without notice or obligation All other trademarks remain the property o...

Reviews: