Icom CY 6000 Instruction Manual Download Page 7

2

INSTALLATION AND CONNECTIONS

■ 

Unpacking

After unpacking, immediately report any damage 
to  the  delivering  carrier  or  dealer.  Keep  the 
shipping cartons.
For  a  description  and  a  diagram  of  accessory 
equipment included with the CY FR series, see 
‘Supplied accessories’ of this manual.

■ 

Selecting a location

Select  a  location  for  the  repeater  that  allows 
adequate  air  circulation,  free  from  extreme 
heat,  cold,  or  vibrations,  and  away  from  TV 
sets,  TV  antenna  elements,  radios  and  other 
electromagnetic sources.

■ 

Antenna connection

For  radio  communications,  the  antenna  is  of 
critical importance, along with output power and 
sensitivity.  Select  antenna(s),  such  as  a  well-
matched  50 

Ω

  antenna,  and  feedline.  1.5:1  or 

better of Voltage Standing Wave Ratio (VSWR) 
is recommended for desired band. Of course, the 
transmission line should be a coaxial cable. 

  CAUTION: Protect repeater from lightning    
  by using a lightning arrestor.
  NOTE: There are many publications    

 

  covering proper antennas and their    

 

  installation. Check with your local dealer for  
  more information and recommendations.

■ 

Duplexer

A  duplexer  is  separately  required  when  only 
one  antenna  is  used  for  both  transmitting  and 
receiving.  Select  a  duplexer  according  to  the 
transmitting and receiving frequencies. Ask your 
Dealer for details. 

■ 

Grounding

To prevent electrical shock, television interference 
(TVI),  broadcast  interference  (BCI)  and  other 
problems,  ground  the  transceiver  through  the 
[GND] terminal on the rear panel.
For  best  results,  connect  a  2-gauge  wire  to  an 
8-foot  long  earth-sunk  copper  rod.  Make  the 
distance between the [GND] terminal and ground 
as short as possible.

WARNING: 

NEVER

 connect the    

 [GND] terminal to a gas or electric pipe,  

 

 since the connection could cause an   

 

explosion or electric shock.

  TYPE-N CONNECTOR INSTALLATION EXAMPLE

Slide the nut, flat washer, rubber gasket and clamp over the coaxial 
cable, then cut the end of the cable evenly.

Strip the cable and fold the braid back over the clamp.

Soft solder the center conductor. Install the center conductor pin and 
solder it.

Carefully slide the plug body into place aligning the center conductor 
pin on the cable. Tighten the nut onto the plug body.

   

 

 

 

30 mm 

 9⁄8 in 10 mm 

 3⁄8 in 1–2 mm 

 1⁄16 in     

4

Summary of Contents for CY 6000

Page 1: ...INSTRUCTION MANUAL VHF FM REPEATER CY 5000 UHF FM REPEATER CY 6000...

Page 2: ...nal part or connectors on the rear panel of the repeater This may result in an electric shock NEVER expose the repeater to rain snow or any liquids AVOID using or placing the repeater in areas with te...

Page 3: ...ration FEATURES Automatic battery backup and charging system A built in backup system supports automatic switching to an external battery 13 6 V DC if the AC power supply fails Other features PC progr...

Page 4: ...modular jack accepts the optional Field Service Aid 1 PANEL DESCRIPTION Front Panel 1 8 V DC output Max 15 mA Output port for PC programming AFO M PTT Input port for TX control Microphone ground Micro...

Page 5: ...nnector AC POWER SOCKET AC Connects the supplied AC power cable to a 120V or 220V AC outlet 120V or 220V internal jumper selectable GROUND TERMINAL GND Ground the repeater through this terminal to pre...

Page 6: ...Active L 16 EXT I O 16 The desired function can be assigned Default P0 Monitor Output 5 V pull up Active L 17 EXT I O 17 The desired function can be assigned Default Busy Output 5 V pull up Active L...

Page 7: ...your local dealer for more information and recommendations Duplexer A duplexer is separately required when only one antenna is used for both transmitting and receiving Select a duplexer according to...

Page 8: ...th following current capacity Solder or clamp the cable plug when connecting the power cable to the backup battery to prevent voltage drops Power cable current capacity 25 A or more TX TX RX ANT RX AN...

Page 9: ...ould result in fire risk An International AC power cable is available The internal AC power supply is jumper selectable between 120Vac and 220Vac In DC operation CAUTION Voltages greater than 16 VDC w...

Page 10: ...is installed or adjust the internal units etc CAUTION Disconnect the AC power cable and or DC power cable from the repeater Otherwise there is danger of electric shock and or equipment damage Remove...

Page 11: ...ed from the speaker Transmitting for Local Control Take the microphone off hook Wait for the channel to become clear Push and hold PTT to transmit then speak into the microphone at your normal voice l...

Page 12: ...the repeater stops functioning try to find the source of the problem and replace the damaged fuse with a new rated fuse 9 CAUTION DISCONNECT the DC power cable from the repeater Otherwise there is a...

Page 13: ...5 250 VAC 50 60 hz 13 6 VDC nominal 16 2 Amp Max Dimensions Projections 480 W x 133 H x 364 D mm not included 18 90 W x 524 H x 14 33 D in Weight 8 6 kg 18 lb 10 Optional Duplexer and Preselector spec...

Page 14: ...E HM 152T DTMF MICROPHONE Hand microphone with a DTMF keypad SM 25 DESKTOP MICROPHONE SP 22 SPEAKER IAS VHF DUP KIT VHF duplexer kit with RF jumpers IAS UHF DUP KIT UHF duplexer kit with RF jumpers 22...

Page 15: ...MEMO...

Page 16: ...009 Icom America Inc The Icom logo is a registered trademark of Icom Inc All specifications and information is subject to change without notice or obligation All other trademarks remain the property o...

Reviews: