Remote Sensor Installation (Optional)
1. Remove cover from remote sensor housing.
2. Select an appropriate location for mounting the remote sensor.
3. Mount remote sensor unit using hardware provided.
4. Install two wires between remote sensor and thermostat (use shielded cable).
•
Wire 1
should run between the S1 terminal on the thermostat and the S1 terminal on the remote sensor
•
Wire 2
should run between the S2 terminal on the thermostat and the S2 terminal on the remote sensor
5. Disable the main sensor (R12) on the thermostat by cutting it from the circuit board.