456DUO
Dual Balance Charger/Discharger/DC Power
- 20 -
1. For example, a 12V/60W bulb as the load of To Channel, it should set Voltage Limit =12V
;
Current Limit=60/12=5A.
2. When the battery as the load of To Channel, Voltage Limit and Current Limit are not settable
,
see details on
LiPo/LiIo/LiFe/LiHV/LTO/NiZn/User Discharge Advanced Setup
Click "
Advanced
" to enter
DISCHARGE ADVANCED SETUP
interface.
1. Tick
Extra Discharge Enable
to activate discharge enable, see more details on
Lithium Battery Extra Discharge
2. Tick
Balance Enable
to activate balance discharge; when discharge enters the CV phase, it starts to balance the cell
voltages.
LiPo/LiIo/LiFe/LiHV/LTO/NiZn/User Discharge Safety Setup
Click "
Safety
" to enter
DISCHARGE SAFETY SETUP
interface.
LiPo/LiIo/LiFe/LiHV/LTO/NiZn/User Cycle Setup
Select
Program
→
Cycle
to enter
CYCLE SETUP
interface.
LiPo/LiIo/LiFe/LiHV/LTO/User Only Balance Feature
Select
Program
→
Balance Only
to enter
Balance Only
setup interface.
Channel Join:
Resistance or bulbs (default)
Charging battery
Voltage Limit:
2V-32V; default: 12V
Current Limit:
0.05A-45A; default: 1A
Cut-Temp:
20℃-80℃; default: 45℃
Max Capacity:
50%-200%; default: 90%
Safety Timer:
1Min-9999Min; default: off
Cycle Mode
:
CHG
→
DCHG(default),DCHG
→
CHG
,
CHG
→
DCHG CHG, DCHG
→
CHG DCHG,
CHG
→
DCHG STO, DCHG
→
CHG STO
Cycle Count:
1-9999; default: 3
Delay Time:
0Min-9999Min; default: 3Min