NiMH/NiCd Battery Discharge Setup
Select
Program
→
Discharge
to enter
DISCHARGE SETUP
interface.
NiMH/NiCd Battery Discharge Safety Setup
Click "
Safety
" to enter
DISCHARGE SAFETY SETUP
interface.
LiPo/LiIo/LiFe/LiHV/LTO/NiZn/User Discharge Safety Setup
NiMH/NiCd Battery Cycle Setup
Select
Program
→
Cycle
to enter
CYCLE SETUP
interface.
See details about setting on LiPo/LiIo/LiFe/LiHV/LTO/NiZn/User Cycle Setup
Pb Battery Setup
After adding program, it will switch to Pb battery in
Type
option on the
MEMORY SETUP
interface. Set the number of
cells
and
capacity
, after editing all parameters for program, click "
Save
" to save and return to the previous interface.
As shown in above picture, the program of Pb battery has the following modes:
Charge, Discharge
and
Cycle.
Pb Battery Charge Setup
Select
Program→Charge
to enter
PB CHARGE SETUP
interface.
1. The charger first charges with constant current (CC) according to the user setting then turns to constant voltage (CV)
when the charging voltage reaches the peak point. In the CV phase the current gradually falls, and the charger will
terminate charging when the current falls below the percentage of the configured charge current.
2. Charge mode has Normal, Reflex two modes available, about the Reflex mode (Reflex) please see
Important Notes
.
Pb Battery Charge Advanced Setup
Click "
Advanced
" to enter
PB ADVANCED SETUP
interface,
Discharge Current:
0.05A-45A; default: 2A
Discharge Voltage
:
0.1V- 27V; default: 0.8V
End Current:
1%-100%; default: 50%
Regenerative Mode
:
OFF (default), To input, To channel
Chg Current:
0.05A-45A; default: 2A
Chg Mode:
Normal (default), Reflex
Chg End Current:
1%-50%; default: 10%
Chg Cell Volt:
2V/Cell-2.6V/Cell; Default: 2.4V/Cell
Cells:
2 -15S; default: 6s
Capacity
:
Ignore(default),50-999900mAh