iCharger Synchronous Balance Charger/Discharger
4010DUO
- 19 -
LiPo/LiIo/LiFe Battery Charge Advanced Setup
Click "
" to enter
LiPo/LiIo/LiFe Battery ADVANCED SETUP
, after setting, click"
"to return to the
previous interface.
Note: 1. When charging the over-discharged battery, the charger will detect if the cell voltage is larger
than the restore voltage, if larger, it will pre-charge the battery with restore current, if within
the setting restore time, the cell voltage rises to the normal value then it will turn to the
charging program; otherwise it will stop running.
2. After charging, the battery may not be completely charged; tick
Keep charging after the done
to charge the battery with smaller current when charging ends.
LiPo/LiIo/LiFe Battery Charge Safety Setup
Click "
" to enter
CHARGE SAFETY SETUP
, after setting click"
" to return to the previous interface.
Note:
Cut-Temp.
is the maximum safety temperature of the battery. If the temperature sensor detects
the set value, the program will stop running in order to protect the battery from being damaged
by high temperature.
LiPo/LiIo/LiFe Battery Storage Setup
This mode is for storing LiPo/LiIo/LiFe battery that will not to be used for an extended period. The charger determines
whether to charge or discharge the battery based on the configured target voltage. If the battery voltage exceeds the
target storage voltage it will start to discharge, while lower than the target storage voltage it will start to charge.
Select
Program
→
Storage
to enter
Storage
setup interface.
Note: 1.
Accelerated storage:
accelerated storage via internal resistance correction. Tick
Accelerated
storage
to activate accelerated storage.
2.
Storage Compensation
is the compensation for the battery voltage fallback: for storage charge,
the actual storage voltage=Storage Cell V Storage Compensation; for storage discharge,
the actual storage voltage=Storage Cell Voltage - Storage Compensation.
Restore Lowest Voltage:
0.5V/Cell-2.5V/Cell; Default: 1V/Cell
Restore Charge Time:
1Min-5Min; default: 3Min
Restore Charge Current:
0.02A-0.5A; default: 0.1A
Cut-Temp
:
20
℃
-80
℃
; default: 45
℃
Max Capacity:
50%-200%; default: 120%
Safety Timer:
0Min-9999Min; default: off
Storage Cell Voltage:
3.7V/Cell-3.9V/Cell;
Default: 3.85V/Cell
Storage Compensation:
0V/Cell-0.2V/Cell;
Default: 0.01V/Cell