Pre-charging a Lithium battery 

If the battery is over-discharged and the voltage is too low then in the Normal charge or Fast charge modes 
the 

iCharger 

will  notify  the  user  of  pre-charging  with  a  low  current  (100mA).  This  helps  to  increase  the 

battery voltage to the within the allowable range for normal charging. The user can set the pre-charging time 
in the 

Lithium Check time 

screen

 

in the 

User setup.

     

 

 

 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 

 

“Storage” 

charge/discharge a Lithium battery

 

This mode is for charging/discharging a Lithium battery that is not to be used for an extended period. The 
program determines whether to charge or discharge the battery based on the configured target voltage and 
the measured initial voltage of the battery. The nominal target storage voltage depends on the type of Lithium 
battery: 3.75V/cell for Lilo, 3.85V/cell for LiPo and 3.3V/cell for LiFe. If at the start the battery voltage exceeds 
the target storage voltage the program will start to discharge rather than charge. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 

Storage of Lithium battery. The left side of the first line set the type of battery 
(LiPo,  Lilo  or  LiFe).  The  value  on  the  left  side  of  second  line  sets  the 
charge/discharge current and the value on the right side of second line sets 
the cell count and voltage of the battery pack. After setting the current and 
voltage,  press 

Start/Enter

  for  more  than  3  seconds  to  start  the  next 

process.   

Charge current: 0.05 

 10A, Voltage: 1 

 6 series   

 
The number of cells you set and the processor detects. The left side of the 
first line ‘R:xxSER‘ shows the number of cells detected by the 

iCharger

 and 

the right side of the first line ‘S:xxSER‘ is the number of cells set by the user. 
If  the  numbers  are  different  you  should  make  sure  that  the  configured 
number and the actual number for the battery are the same and then you 
can start charging by pressing 

Start/Enter

. If not, press 

Batt type/Stop

 to 

go back to the previous screen and adjust the setting. 
 
Lithium STORAGE charging mode. The screen shows the status during the 
charging  process.  You  can  stop  charging  at  any  time  by  pressing 

Batt 

type/Stop

.  Press 

Inc

 

to  display  each  cell‘s  voltage  (see  the  balance 

voltage  information)  and  press 

Dec 

to  display  the  General  Status 

information. 
 

   

 

 

R:03SER  S:03SER 
CONFIRM(ENTER)

 

 

Battery 

Series

 

V-BP

 

Charge 

Current

 

   

 

 

Li03 1.0A 12.60V 
STO 00993 59m:51 

battery 

voltage 

number 

of cells 

 

eries 

charged 

capacity

 

charging 

time 

charge 

current 

work 

state 

Start/Enter 
 

Batt type 

stop

 

Start/Enter 

>3 seconds 
 

Batt type 

stop

 

   

 

 

LiPo STORAGE 
1.0A   11.1V(3S)

 

 

Dec

 

Inc

 

 

Dec

 

Inc

 

 

Dec

 

Inc

 

 

The  following  screen  is  displayed  when  the  charger  detects  the  battery 
voltage to be too low in the Normal charge or Fast charge modes. 
   
 
Pre-charge lithium battery. Press 

Start/Enter 

to start the charging process 

or press

 Stop 

to go back to the previous screen. 

 
 
 
Status display. The left side of the first line shows the type of battery (LiPo, 
Lilo or LiFe) and number of cells detected. In the middle is the pre-charge 
current (100mA). On the right is the voltage of the battery pack. The second 
line shows the charging progress with capacity charged (mAh) and charging 
time. The charger will switch back to the configured charge mode when the 
pre-charge time limit is reached. You can stop the pre-charging process at 
any time by pressing the 

Batt type/Stop 

button. 

   

 

 

Do checking? 
CONFIRM(ENTER)

 

 

   

 

 

Li03 0.1A 12.40V 
CHK 00001 00m:51 

battery of 

cells test 

online

 

charged 

capacity 

charging 

time

 

0.1A 

pre-charge 

current 

battery 

voltage

 

work 

state

 

Pre-charging battery 

Start/Enter 
 

Batt type 

stop

 

Summary of Contents for 106B+

Page 1: ......

Page 2: ...thium Battery External Expanding Discharge Mode 17 Cycle Mode for a Lithium Battery 18 Lithium Battery in Monitoring Mode 18 NiCd NiMH Battery Program 19 Charging a NiCd NiHM Battery 19 Discharging a NiCd NiMH Battery 19 Cycle Mode for a NiCd NiMH Battery 19 NiCd NiMH Forming Charge 20 Pb lead acid Battery Program 21 Charging a Pb Battery 21 Discharging a Pb Battery 21 Special Modes Program 22 Ele...

Page 3: ...can be used with three types of Lithium batteries LiPo Lilo LiFe and has a fully integrated cell balancer Internal temperature sensor and temperature controlled automatic cooling FAN controls the internal temperature and provides intelligent protection When the internal temperature is over 60 140 o F the output power is automatically reduced by 25 If the temperature exceeds 65 149 o F the charge c...

Page 4: ...an measure the per cell internal resistance only available for lithium battery Perfect protection The iCharger has protection for reversed polarity input or output low input voltage battery temperature charging capacity and time overrun Support upgrading the hardware program by USB port The iCharger also support the logview software and can display plot and analyze the charge and discharge data by...

Page 5: ...ne pair of output alligator clip leads One pair of input alligator clips 30A and input leads with 4mm bullet connectors One temperature sensor lead 0 99 210 o F Four rubber feet One Mini USB data line 1 2 meter Optional items See details in Optional parts P29 External controls and connections 106B 1 DC input 2 LCD screen 3 Function button 4 Cooling Fan 5 Temperature sensor port 6 Balance socket 7 ...

Page 6: ...t charge or discharge on a carpet cluttered workbench paper plastic vinyl leather or wood inside an R C model or inside a full sized automobile Never block the air intake holes and never use in a refrigerated or high temperature environment If used in such an environment the internal temperature protection may result in abnormal charging discharging that could be dangerous Do not allow water moist...

Page 7: ...RAM SELECT Save settings PROGRAM SELECT Load settings SAVE SETTINGS XX memoryX LOAD SETTINGS XX memoryX Batt type Dec Inc PROGRAM SELECT Special modes MOTOR DRV XXmin X XA XX XV Completion Ring Beep XXX Back light XX Cooling fan XXXX Capacity Cut Off XXX XXXXXmAh NiMH NiCd Pb Trickle XXXmA NiMH Sensitivity DeltaV XXmV Cell Lithium battery Check Time XXmin Bal Speed XXXXXX Bal Trickle XXX Temp Cut ...

Page 8: ...ter together for more than 3 seconds to obtain this display Standard battery parameters LiPo LiIo LiFe NiCd NiMH Pb Nominal voltage 3 7 V cell 3 6 V cell 3 3 V cell 1 20 V cell 1 20 V cell 2 0 V cell Max charge voltage 4 2 V cell 4 1 V cell 3 6 V cell 1 60 V cell 1 60 V cell 2 45 V cell Storage voltage 3 85 V cell 3 75 V cell 3 3 V cell n a n a n a Allowable fast charge current 1C 1C 4C 1C 2C 1C 2...

Page 9: ...w If Bal Trickle is ON the iCharger won t stop charging until the current falls to around 20mA Bal Speed Fast Normal Slow Normal default Bal Trickle OFF ON OFF default For balance charging Li battery There are three balance modes options CV phase storage voltage and always If the balance mode is set to CV phase when any cell s voltage reaches the set voltage for CV it will enable the balancer When...

Page 10: ...tion lower limit The charging discharging process will stop immediately if the input voltage falls below the set value Range 10 00 15 00V 10 00V default Charge Discharge power limit The maximum charge discharge power of iCharger can be adjusted in order to limit internal temperature and to protect the input current from over loading When the limit is set to AUTO the iCharger can adjust the output ...

Page 11: ...tion voltage Press Start Enter for more than 3 seconds to blink the Voltage value then press Dec and Inc to adjust the termination voltage Range 3 40V 3 90V Step 0 01V 3 60V default Termination voltage for Lilo Adjust Lilo s charge termination voltage Press Start Enter for more than 3 seconds to blink the Voltage value then press Dec and Inc to adjust the termination voltage Range 3 90V 4 20V Step...

Page 12: ...age for the selected chemistry cell_discharge_voltage configured per cell storage voltage for the selected chemistry Icv charge current during the CV phase Any time the battery s balance lead is connected the charger will monitor and display the cell voltages The balancer is only active during a BALANCE charge not during the CHARGE or FAST programs The balance speed setting Slow Normal Fast contro...

Page 13: ... Charge current 0 05 10A Voltage 1 6 series The number of cells you set and the processor detects The left side of the first line R xxSER shows the number of cells detected by the iCharger and the right side of the first line S xxSER is the number of cells set by the user Usually the auto detect number won t exceed the number set by the user If the numbers are different you should make sure that t...

Page 14: ...You can stop charging at any time by pressing Batt type Stop Press Inc to display each cell s voltage see the balance voltage information and press Dec to display the General Status information battery voltage number of cells Series charged capacity charging time charge current work State The fast charging mode of Lithium battery The left side of the first line set the type of battery LiPo Lilo or...

Page 15: ...of cells set by the user If the numbers are different you should make sure that the configured number and the actual number for the battery are the same and then you can start charging by pressing Start Enter If not press Batt type Stop to go back to the previous screen and adjust the setting Lithium STORAGE charging mode The screen shows the status during the charging process You can stop chargin...

Page 16: ...the left side of second line sets the charge current and the value on the right side of second line sets the cell count and voltage of the battery pack After setting the current and voltage press Start Enter for more than 3 seconds to start the next process Per cell final voltage LiPo 3 00 4 20V Lilo 2 50 4 10V LiFe 2 00 3 60V Discharge current 0 05 7A Cell count 1 6S The number of cells you set a...

Page 17: ... cell count and voltage of the battery pack After setting the current and voltage press Start Enter for more than 3 seconds to start the next process Per cell final voltage LiPo 3 00 4 20V Lilo 2 50 4 10V LiFe 2 00 3 60V Discharge current 0 05 7A Cell count 1 6S The number of cells you set and the processor detects The left side of the first line R xxSER shows the number of cells detected by the i...

Page 18: ... process you can stop the cycle at any time by pressing the Batt type Stop button In the process of C D or D C the blink C indicates charging while D indicates discharging Press Inc button to display each cell s voltage and its past cycling current see the balance voltage information cycling information and press Dec button to display the General Status information During the waiting time of disch...

Page 19: ...ng Batt type Stop Press Dec to display the General Status information NiMH DISCHARGE 1 0A 7 0V Start Enter 3 seconds Batt type stop The left side of the first line shows the type of battery NiCd NiMH and the right shows the cycle number The second line shows the cycle direction you selected CHG xxx DCHG or DCHG CHG xxx You can set the charge mode as Charge Auto or Charge Manual The discharge param...

Page 20: ...he type of battery NiCd NiMH The value on the left side of second line sets the cell capacity and the value on the right side of second line sets the cell count and nominal voltage of the battery pack Press Start Enter for more than 3 seconds to start charging Forming capacity 0 1 9 9Ah Cell count 1 17S Forming status You can stop the process at any time by pressing Batt type Stop and display the ...

Page 21: ...e charging Charge current 0 05 10A Battery cells 1 12P 2 24V Status display You can stop the charging process at any time by pressing Batt type Stop Press Dec to display the General Status information Discharging Pb battery The left side of the first line shows the type of battery Pb The second line shows the charge current on the left and number of cells on the right After setting the current and...

Page 22: ...ght corner alternately displays the output power or total run time You can stop the test at any time by pressing Batt type Stop Start Enter 3 seconds Batt type Stop MOTO 1 9A 2 05V DRV 00310 3 8W drive voltage drive capacity power or time drive current work state motor test MOTOR DRV 10min 8 0A 2 0V Dec Inc Dec Inc The value on the right side of the first line sets the run duration in minutes The ...

Page 23: ...nternal resistance only available for lithium battery Note You can check the internal resistance by Present testing information see detail information in Page 8 Start Enter 3 seconds Batt type Stop 1 21 24 19mΩ 4 18 26 16mΩ Measure Internal Resistance Measure internal resistance You can press Start Enter for more than 3 seconds to start the process and stop at any time by pressing Batt type Stop T...

Page 24: ... 00 refers to the target memory number the user wants to choose In the second line the memory0_ refers to the character the user wants to input Press Inc Dec button to walk letters and then press Start Enter button to confirm the chosen letter and moves to the nest letter position when you finish the character press Start Enter button twice to confirm the character You can delete a wrong chosen le...

Page 25: ...r has been reported press Batt type Stop to return to the main menu Press Inc or Dec to check the parameter value related to the error For example in the case of a temperature error you can check the temperature that triggered the error Press Start Enter to return to the error message screen Expression refers to the discharged capacity to packs Termination at 01245mAh 01h 32 Termination time Termi...

Page 26: ...thout using the balance port the cell count detected by the charger is less than that set by the user Please check the cell count of the battery pack Without using the balance port the cell count detected by the charger is higher than that set by the user Please check the cell count of the battery pack The internal temperature is over 65 149 o F Cool down the unit The external temperature sensor d...

Page 27: ...steps Install the iCharger USB driver Run the program X Upgrader Upgrader exe you can download the Upgrader exe software from the following website http www jun si com UploadFiles Upgrader rar Connect the iCharger to the PC using the supplied USB cable choose Device in Device List then select the upgrade file you can download the latest file The progress bar will appear after you click Update Note...

Page 28: ...ive Connect the iCharger with PC USB driver has been installed Start logview then follow the instructions in pictures 1 Please choose language first since the default language is German Showed in picture 1 2 Click Device Choose device and port Showed in picture 2 1 2 3 Choose iCharger106 in the following options and then choose the correct communication Port Showed in picture 3 3 4 Start iCharger ...

Page 29: ... with magnet 4mm banana gold plug to JST output wire 4mm banana gold plug to T plug output wire Power supply Specifications Input Voltage Range 100 240VAC Input Frequency 50 60Hz Output Voltage 14 9 15 5VDC Output Current 0 23A Operating Temperature 10 40 Storage Temperature 40 80 Dimension L X W X H 185 X 88 X 47mm Weight 700g CB1010 XH 70 X 44mm CB1010 EH CB1010 AQP CB1010 TP 70 X 44mm 68 X 51mm...

Page 30: ...e power supply automotive battery charger etc water moisture and humidity are specifically NOT covered by warranty It is best to carefully check your charger before considering returning it as problems in setup cabling or power supply are much more common than defects in the charger If there is damage stemming from these causes within the stated warranty period the company will at its option repai...

Reviews: