-11-
iCharger Synchronous Balance Charger/Discharger 106B+
LiPo Termination
Voltage 4.20V
Back-light 50%
Cooling fan AUTO
Completion Ring
Beep always
-
Dec
+
Inc
Inc
Dec
-
Dec
+
Inc
LiFe Termination
Voltage 3.60V
Delay 0min
Lilo Termination
Voltage 4.10V
Inc
Dec
-
Dec
+
Inc
Inc
Dec
-
Dec
+
Inc
-
Dec
+
Inc
Process completion tone. Controls the tones generated at end of
charging or discharging and the cyclic charging/discharging indication.
Options: Beep 5 times, Beep 3 minutes, Beep always (continuous
until user presses STOP), Beep OFF
(Beep always, default)
Back-light and cooling fan control. Adjust the
LCD backlight brightness.
There are three cooling fan modes: ON, OFF, AUTO. In AUTO-Mode,
iCharger
adjusts the fan automatically to control its internal temperature.
Cooling fan: OFF, ON & AUTO (AUTO, default)
Discharge reduce setting. When you set it to ―ON‖
,
If the final voltage
target storage voltage is reached, the buzzer will beep for three times,
and the left of the second line display "D>>", and the charger enters into
the high precision discharge process. The process won‘t stop until the
current reaches xx% of the configured discharge current.
Reduce: ON, OFF Range: 1
–
99
%
Termination voltage for LiFe. Adjust LiFe‘s charge termination voltage.
Press
Start/Enter
for more than 3 seconds to blink the ―Voltage‖ value,
then press
Dec
and
Inc
to adjust the termination voltage.
Range: 3.40V
–
3.90V, Step: 0.01V (3.60V, default)
Termination voltage for Lilo. Adjust Lilo‘s charge termination voltage.
Press
Start/Enter
for more than 3 seconds to blink the ―Voltage‖ value,
then press
Dec
and
Inc
to adjust the termination voltage.
Range: 3.90V
–
4.20V, Step: 0.01V (4.10V, default)
Termination voltage for LiPo. Adjust LiPo‘s charge termination voltage.
Press
Start/Enter
for more than 3 seconds to blink the ―Voltage‖ value,
then press
Dec
and
Inc
to adjust the termination voltage.
Range: 4.00V
–
4.30V, Step: 0.01V (4.20V, default)
Termination voltage for Pb. Adjust Pb‘s charge termination voltage. Press
Start/Enter
for more than 3 seconds to blink the ―Voltage‖ value, then
press
Dec
and
Inc
to adjust the termination voltage.
Range: 2.20V
–
2.50V, Step: 0.01V (2.40V, default)
Note:
The Termination voltage controls the transition from Constant
Current (CC) to Constant Voltage (CV) charging for LiXx and Pb
chemistries. It also defines the per-cell limit for cell overvoltage detection.
If you change the default termination voltage, the charge and discharge
setting screen will note this difference by alternatively blinking battery‘s
type and setting voltage value.
Inc
Dec
Pb Termination
Voltage 2.40V
Inc
Dec
-
Dec
+
Inc
Discharge reduce
OFF 50%
Delay 0min
-
Dec
+
Inc
-
Dec
+
Inc
Inc
Dec
Summary of Contents for 106B+
Page 1: ......