14
Functional description of the buttons
If you press the "Set" button lightly, you can
enter the mode to check the setting as below.
Use the "▼" and "▲" buttons to see the
settings.
【 Change the setting 】
1-1 : Check ice cream level settings
You can check the current setting for the ice cream. If the
displayed value is higher than the no-load current (1-2),
the ice cream becomes harder and if lower,
the ice cream becomes softer.
1-2 : Check the ice cream default level
It is the no-load current of the dasher motor.
It is the current consumed by the dasher motor
when the ingredients are in the liquid status.
1-4 : Check the storage temperature in the mixing tank.
You can check the temperature inside the mixing tank.
1-5 : Check the voice announcement
You can check whether a voice announcement
is available.
1-6 : Check the program version
You can check the versions of the main PCB
and the display PCB.
"n" is for the main PCB and "d" is for
the display PCB.
For your
information
The soft cream level is set for the ingredients (vanilla) designated by the maker.
Depending on the ingredients, you will need to adjust it properly. Please follow the
instructions from our company when changing the level for the ingredients.
1-3 : Check the currently supplied voltage.
It is the power supplied to the machine.
If the voltage is not correct after installation,
call for service.
Summary of Contents for ISI-322ST
Page 30: ...30 Circuit diagram...
Page 31: ...31 Part list...
Page 32: ...32 Part list...
Page 33: ...33 Part list...
Page 34: ...34 Part list DASHER ASSY...
Page 35: ...35 Part list REFRIGERANT...
Page 36: ...36 Part list ASSY CONTROL BOX...
Page 37: ...37 MEMO...
Page 38: ...3240312 00 Online Internet Service http www icetro com...