19
[ A u t o ] I c e c r e a m L e v e l
[ A u t o ]
[ T e m p e r a t u r e ]
6 0 % / 6 0 %
N o w L o a d : 1 . 2 A / 1 . 2 A
S e t L o a d : 1 . 5 A / 1 . 5 A
N o L o a d : 1 . 0 A / 1 . 0 A
H o p p e r : 8 . 2 °C / 8 . 2 °C
D r u m : - 6 . 2 °C / - 6 . 2 °C
B r e a k T i m e
8 . 0 m i n / 8 . 0 m i n
Functional description of the buttons
【
Detail description of each mode
】
Making soft ice cream in ‘AUTO’ mode.
To check ‘AUTO’ mode level set up
After making soft ice cream in
the ‘AUTO’ mode.
To see the raw material information of the
mixing tank in the ‘AUTO’ mode
Pour the raw material in the mixing tank and press the
‘AUTO’ button. The following status display will be shown.
To see the information of the raw material in the hopper,
press ‘SET’ button:
When soft ice cream has produced,
the compressor will be shutdown for a while, and
the status will be displayer as shown to the right.
①
Current level of soft ice cream is indicated.
④
Information including the temperature of the hopper
and cylinder can be obtained.
③
At Operation mode, if you push ‘DEC.’ button
1 time, piston time decreases by 0.1 second.
If you push ‘INC.’ button 1 time, piston time
increases by 0.1 second.
(Max : Values of
‘3-8-2 ’ or ‘3-10-2 ’ of each mode)
⑤
The time remaining until the restarting of the compressor
will be displayed in Min unit.
(If the ambient temperature is high, the compressor may
start up earlier than the time indicated.)
②
Press the ‘SELECT’ button to display the level
setting (Current, Set-up, No-load) of soft ice cream.
to change soft ice cream level setting, press the
‘SET’ button for three seconds.
(For futher details, see ‘Adjusting Setting
Value’ section.)
②
⑤
To change temperature, press the ‘SET’button for
three seconds.
(For further details, see
‘
Adjusting Setting Value
’
section.)
⑥
Soft ice cream level is indicated.
(After indicating 100%, the value will decrease as time
passes, faster if the ambient temperature is higher.).
The soft ice cream level is set to the default by the manufacturer. Depending on the types of ingredients
and the abrasion of the blade, it should be adjusted properly. When installing this equipment,
the settings for the ingredients should be based on the suggestion by the installation technician.
When changing the ingredients, consult with a professional to adjust the setting.
④
⑥
For your
information
[ A u t o ] I c e c r e a m L e v e l
6 0 % / 6 0 %
B r e a k T i m e
8 . 0 m i n / 8 . 0 m i n
③
①
M i d d l e
1 . 5
[ A ]
M i d d l e
1 . 5
[ A ]
Summary of Contents for ISI-271SHS
Page 75: ...75 Wire diagram...
Page 82: ...MEMO 82...
Page 83: ...MEMO 83...
Page 84: ...MEMO 84...
Page 85: ...3240229 06 Online Internet Service http www icetro com...