Poor maintenance, leaking gaskets/bolts, or a plugged drain can destroy a machine: If bolts
at the top extruder or lower housing assembly leak, scale can build up on the urethane
insulation, the lower housing assembly, and/or the gear box and destroy those parts.
When removing bolts, new o-rings and/or new bolts with o-rings should be used.
If bolts are not tightened properly (or o-rings damaged) the leaks above will occur.
Should the drain pan’s drain line
become plugged, it will overflow and
cause scale to greatly damage unit.