If the temperature of the ICE MAKING water supply is too high, the amount of ICE MAKING
may be reduced, If the water pressure is too low, it may not be possible to freeze.
In this case, an auxiliary hydraulic pump should be installed.
Connect the ø6.35 PE TUBE to the bottom right of the product as shown in the picture
and secure the clip to prevent hose detachment.
[ Connection of water and drainage hoses ]
Division
Proper water temperature
Water pressure
Hose to be used
ICE MAKING water supply
50~90℉
20~80psi
NPT 3/8"
ICE MAKING drainage
-
-
NPTF 3/4"
Connection method of water supply and drainage
Please connect a hose with an inner diameter of Φ20mm(Φ0.78") or more for the ice
making drain hose and the drain outlet should be 5cm(1.97") above the drain floor level.
(If the drain outlet dip in the drainage, the drainage may flow back into the ice maker
and damage the product and the floor.)
※ After the installation is complete, please operate the product and check whether
there is leakage in the water supply and drainage parts.
Be careful not to bend the drainage hose during
the installation and also confirm that the hose is not
exposed to fire or sharpness which may result
in the hose burst.
(This will become the cause of the PL accident
and the manufacturer shall not be held responsible.)
Water inlet
Drain outlet
Drain floor level
Ice-maker drain outlet
Drain box
5cm(1.97")or more
Option