WASH CYCLE FOR ALL IU-SERIES MACHINES
1.
With the power switch in the ‘OFF’ position, add the
appropriate amount of ice machine cleaner or sanitizer to the water trough.
NOTE: If the machine is in the ‘ICE’ mode, first place the
power switch in the ‘OFF’ position and wait for the
machine to finish its current cycle and stop.
2.
Place the power switch on the front panel to the ‘WASH’ position to run the wash cycle.
3.
Water inlet solenoid valve opens for a 30 seconds to fill.
4.
Water pump then runs for 10 minutes, circulating the mix through the water trough, pump,
connecting hose, water distributor, and evaporator.
5.
Dump valve solenoid opens for a 40 second flush.
6.
Water inlet solenoid valve opens for a 30 second fill.
7.
Water pump then runs for 1.5 minutes to circulate fresh water.
8.
Dump valve solenoid opens for a 40 second flush.
9.
Steps 5-7 repeats five times.
WARNING! Do NOT mix ice machine cleaner and sanitizer together. Use one or the other separately.
Mixing cleaner & sanitizer together can cause severe bodily injury.
WARNING! Use ONLY nickel safe ice machine cleaner.
Summary of Contents for IC Series
Page 1: ...Under Counter Installation Service Manual IC Series IU Series...
Page 2: ...2 Under Counter Spec Sheet...
Page 3: ...3 Under Counter Spec Sheet...
Page 23: ...Lamp Indicators Under Counter 23...
Page 24: ...24 Under Counter Wiring Diagram...
Page 25: ...25 Under Counter PCB...
Page 26: ...26 Under Counter PCB...
Page 29: ...29 Under Counter PCB UnderCounterFlushTimeAdjustment...
Page 30: ...30 Under Counter Refrigeration Circuit...
Page 31: ...31 Under Counter Refrigeration Circuit...
Page 32: ...32 Under Counter P T Chart Cycle Times...
Page 33: ...33 Under Counter Service Tips Pinching Tubing Re rounding Tubing...
Page 37: ...THANK YOU 1 15 2022...