MANUAL for kg20 kg6 kg6 bAsic
dr
y
ic
e
bl
a
sting
eq
uipm
ent
fro
m
icetech
|
P
A
ge
6
6
2
2
activate the trigger switch on the blasting gun
for a few seconds for activating the battery
indicator / digital control display.
check that the battery is fully charged
(battery indicator).
adjust the blasting pressure
(the working pressure).
activate the trigger switch on the blasting gun
for a few seconds to allow air to
flow
through
the system.
6
place the dry ice pellets into the dry ice tank.
adjust the consumption of dry ice.
start blasting.
sHUTTiNg DoWN
THe icebLAsT MAcHiNe
When the cleaning task has been completed, the
following procedure must be carried out before the
machine is dismantled or stored:
• empty the dry ice tank.
• activate the trigger on the blasting gun for a few
seconds in order to empty the system of pos-
sible dry ice residue.
• close the main compressed air supply.
• activate the trigger switch on the blasting gun
again for a few seconds in order to depressurise
the system.
• make sure that the emergency stop is in off
position -when pushed in.
• disconnect the main air supply.
• avoid kinking the blasting hose, especially when
rolling it up.
eMergeNcY sToP
activation of the emergency stop immediately stops
the blasting air stream and dry ice dispensing.
before the machine can be restarted, the following
procedure must be carried out:
• the emergency stop must be put back to the
correct operating position.
• the blasting air stream can now be restarted by
activating the trigger switch on the blasting gun.
fAiLUre/fAULTs
if when using the machine the operator notices that
the outer protection sleeve on the blasting hose
looks or feels
inflated
in any way, the machine must
be stopped immediately.
• close the main air supply immediately.
• activate the trigger switch on the blasting gun
until the system is depressurised.
• activate the emergency stop.
• remove the main air connections from the machine.
• remove the blasting hose and send it for repair
and pressure testing at the manufacturer’s test
facilities.
• the dry ice tank might be empty, but the
system must not be blasted through until a new/
repaired blasting hose has been connected.