GB
4
ALLACCIAMENTO ELETTRICO....
The maximum voltage variation should not exceed
10% of that stated on the rating plate.
The machine should be connected to an indepen-
det fused or suitable power supply protected with
earth. See rating plate for load requirements.
Fix a solid earth ground plug to the electrical
power supply wire of the machine. Be sure the
plug is in conformity with the local electrical code
requirement.
Check by means of a tester the continuity of the
earth mass from the panels to the plug earth termi-
nal board.
FINAL CHECK
a) Check that the supply means voltage corresponds to
that stated on the plate of the machine.
b) Open the shut-off valve of the water supply and check
there are no leaks.
c) Check that the icemaker is properly levelled.
d) Check that the storage bin has been wiped clean.
e) Give the “Operationg instructions” manual to the
owner/user and recommend him on the importance to
observe the instructions and period maintenance.
f) Properly fill in the certification card and mail it to Caste
Mac.
g) Check all refrigerant lines and conduit lines or panels
to guard against vibrations and rubbing.
h) Make sure that the unit is installed in a room where the
ambient temperature doesn’t fall below 10°C even win-
ter months.
i) Check that the water supply pressure is of minimum 1
atm (14 Psi).
l) Give the owner the name and the complet address of
the authorized Service in his area.
1) Swicth
2) Socker
3) Electrical plug
4) Water iniet
5) Shut of valve
6) Water autlet from the condenser:
water cooled version
7) Water autlet from the bin
8) Open vented water
Mod. N25W ÷ N140W
1) Switch
2) Socker
3) Electrical plug
4) Water iniet
5) Suht off valve
6) Water autlet from the condenser:
water cooled version
7) Water autlet from the bin
8) Open vented water
Mod. N25S ÷ N140
Summary of Contents for N140
Page 2: ......
Page 16: ...GB 14 WIRING DIAGRAMS N25S AIR...
Page 17: ...GB 15 N25L N35S AIR...
Page 18: ...GB 16 N25S N25L N35S WATER...
Page 19: ...GB 17 N45S N45L N55S N55L N70S N90S N90L AIR...
Page 20: ...GB 18 N45S N45L N55S N55L AIR...
Page 21: ...GB 19 N50 B I AIR...
Page 22: ...GB 20 N50 B I WATER...
Page 23: ...GB 21 N70S N90S N90L WATER...