GB
9
DIFETTI
CAUSA
RIMEDI SUGGERITI
Icecubes are too low
Icecubes are too long
Unproper shape and/or
irregular dimension of
cubes
Deposits in the pan
Water leaks
c) Air circulation blocked.
d) Non-condensable gases in system.
e) Detective compressor electrical
components.
f) Mechanical or electrical failure inner
compressor.
a) Water level in the pan is too low.
a) Water level in the pan is too high.
b) Water solenoid valve is not water-tight.
a) Incorrect position of revolving paddles.
b) Unit is not properly levelled.
a) Impure water.
b) Calcareous water.
a) Detective water seal.
Move unit to cooler location.
Purge-off.
Replace electrical components.
Remplace compressor.
Adjust level by raising the float ball
micro-swicht assy.
Adjust level by lowering the float ball micro-
swicht assy.
Check the valve in order to remove eventual
obstructions, or replace defective parts.
Center the paddles in accordance with the
evaporator components.
Check the machine level by working with the
adjustable feet.
Clean the water inlet filter.
Install a water softener.
Check and repair.