Controller for Thermoelectric Thermal Management 

 

INSTALLING THE CONTROLLER 

The Ice Qube TMS controller is shipped complete with mounting hardware and electrical cables for easy installation. Cables 
include a power cable for connecting to VDC power supply, VDC power and controller function cables for connecting the 
controller to the thermoelectric thermal management system. 

NOTE:  Installation should be done by a qualified technician.  All electrical connections should be made with 
circuits de-energized.  Check local codes or with authority having jurisdiction. 

1. 

Determine a location for 

the controller.  See drawing for 
mounting hole dimensions and 
requirements.  Check that cable 
length is sufficient to interface 
with power supply and 
thermoelectric unit. 

2. 

Route the DC power 

cable and controller cable 
exiting from the bottom of the 
controller to the thermoelectric 
unit.  Insert the cable connectors 
into the mating connector on the 
thermoelectric unit.  Check the 
connectors are secure. 

3. 

Insert the power cable 

connector (shipped loose) into 
the DC power interface on the 
front of the controller.  Route the 
power cable to Class 2 DC 
power supply.  Check that the 
power supply is properly 
grounded and of sufficient 
capacity to meet the power 
requirements of the 
thermoelectric unit.  See model 
specifications or label for 
electrical power requirements.  
Connect the wires labeled 
positive, negative and ground 
(PE) to the corresponding 
terminals on the power supply.  
Check that all connections are 
proper and secure.  

 

 

Figure 1. Controller Mounting (not to scale) 

 

Summary of Contents for QD-ENG-68

Page 1: ...ments Check that cable length is sufficient to interface with power supply and thermoelectric unit 2 Route the DC power cable and controller cable exiting from the bottom of the controller to the thermoelectric unit Insert the cable connectors into the mating connector on the thermoelectric unit Check the connectors are secure 3 Insert the power cable connector shipped loose into the DC power inte...

Page 2: ... the temperature on the digital display will begin to decrease When the temperature inside the enclosure decreases 7 degrees Fahrenheit below the Cooling on set point the outside fan s will cycle off The cool air fan s will continue to operate at low speed circulating air within the enclosure The controller has a factory programmed 7 degrees Fahrenheit 4 degrees Celsius cooling differential Exampl...

Page 3: ...ack to normal mode from the controller programming mode Press the SELECT button to continue programming and icons indicate the cooling on set point is shown on the controller display The cooling system will begin operation at this temperature and will remain operating until the enclosure temperature decreases approximately seven degrees Fahrenheit four degrees Celsius below the cooling on set poin...

Page 4: ... first key is pressed on the key pad the controller display shows 1 indicating the first digit of the pin code has been entered Numbers 2 3 and 4 are displayed sequentially after pressing the other keys When the fourth digit of the pin code is entered the controller will move on to the next step of the programming If the fourth pin code is not entered within 60 seconds the system will log out auto...

Page 5: ...ions or its speed is over 35 of the set range the controller will give a fan malfunction alarm and the icons fan No will appear on the screen The fan numbers 1 and 2 refer to internal circulating fans 3 4 and 5 refer to external circulating fans and 6 refers to the hydrogen fan The hydrogen fan option is not available for TEC Series 3 The filter day timer has expired The display flashes showing an...

Reviews: