Ice Qube, Inc. ("

Ice Qube

") warrants that the products manufactured by Ice Qube (the "

Products

") are free of defects in material and workmanship 

which impair the operation of the Products, under normal and proper use and service, for a period of one (1) year from the date of shipment FCA 
from Ice Qube’s facility located in Greensburg, Pennsylvania (the "

Standard Warranty

").   

 
In order for this Standard Warranty to apply, the Product(s) must be installed and operated according to and consistent with the following conditions: 
 
Voltage variation no greater than +/- 10% from the rated voltage on the label of the Product; 
Frequency variation no greater than +/- 3 HZ from rated frequency on the label of the Product; 
Ambient temperature must not exceed maximum operating temperature on the label of the Product; 
Maximum cooling capacity not to exceed rating (BTU/HR) as rated on the label of the Product; and 
The Product must be installed, maintained and operated consistent with the terms and conditions set forth in the operation manual. 
 

THIS STANDARD WARRANTY DOES NOT COVER THE FOLLOWING

 
Ice Qube assumes no liability beyond the repair or replacement of its own Products.  In no event shall Ice Qube be liable for any incidental, special, 
indirect, consequential or similar damages incurred by any purchaser, owner, possessor, assignee or successor in interest or any other third party 
having any interest in any Product as the result of any breach of this Standard Warranty, including but not limited to loss of profit or revenues, 
damages for loss of use of the Products, damage to property, both real and personal, claims of third parties, including personal injury or death on 
account of use of the Products or failure of Ice Qube to warn against or instruct on or adequately warn against or instruct on, the dangers of the 
Products or the safe and proper use of the Products, whether or not customer has been advised of the potential for such damages. 
Ice Qube's total liability for customer's claims from any cause whatsoever, whether arising under contract, warranty, tort (including negligence), strict 
liability, products liability or any other theory of liability, will be limited to the lesser of customer's actual damages or the price paid by customer to 
Ice Qube for the Products (not including applicable taxes, duties and freight charges) that are the subject of customer's claim. 
 
THE WARRANTY SET FORTH HEREIN IS STRICTLY LIMITED TO ITS TERMS AND IS IN LIEU OF ALL OTHER WARRANTIES, 
GUARANTEES, EXPRESS OR IMPLIED, ARISING BY OPERATION OF LAW, COURSE OF DEALING, CUSTOM, USAGE OF TRADE OR 
OTHERWISE, SPECIFICALLY EXCLUDING ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR 
PURPOSE OR USE. 
 
The warranty and remedies for breach of warranty provided for in this Standard Warranty extend only to the original installation and do not cover, 
and Ice Qube will neither assume responsibility, nor be liable, for the following:  
 
misapplication of its Products or the erroneous selection of an inappropriate Product by a non-authorized Ice Qube representative;   
use of the Product for other than its designed purpose or operating conditions; 
operation or storage in harsh, oily, corrosive or other abnormal environments without the proper filtration, sealing, protective coatings and/or weather 
protection; 
damage to the hermetic system resulting from continuous operation with dirty or clogged air filters or improper or negligent maintenance; 
use of refrigerant other than designated on the label of the Product; 
customer modification or abuse; 
shipping damage or other accidental damage (It is Ice Qube’s standard policy that freight claims are the responsibility of the customer if the Product 
is not refused at delivery); 
repair, damage or service of the Product caused by anyone except personnel authorized by Ice Qube; 
cracked or broken hermetic tubing, brazed joints or other internal damage caused by shipping or mishandling; 
damage caused by shipping units attached to an enclosure; 
any and all damage, breakage, malfunction or other like conditions or defects resulting from noncompliance with the standard operation, care, 
installation, maintenance and use of the Product as set forth in the operation manual for such Product; 
any cause beyond the control of Ice Qube, including without limitation conditions caused by movement, settlement or structural defects of the 
environment in which the Products are installed; 
fire, wind, hail, flood, lightning or other acts of God; 
any damage to the finish of the Products after they leave Ice Qube's facility;  
any discoloration or spotty appearance of the Products; 
return freight and shipping charges, along with applicable duties and other like fees and charges, for the return of the Product to Ice Qube (such 
amounts are the sole responsibility of the customer); 
failure to process or inaccurate processing of time-sensitive information and/or mechanisms; or 
exposure to harmful chemicals, pollutants or other foreign matter or energy. 
 

 

Summary of Contents for Evolution Series

Page 1: ...cations or Nonhazardous Locations OPERATION AND INSTALLATION MANUAL IMPORTANT PLEASE READ this manual and follow the instructions for safe and satisfactory installation and operation of this system Ke...

Page 2: ...er 14 Alarm Operation 14 Maintenance 15 Trouble Shooting 15 Schematic Wiring Diagrams 17 Ordinary Locations 17 120V 220V 230V 17 400V 460V 480V 18 Hazardous Locations 19 120V 220V 230V 19 400V 460V 48...

Page 3: ...thin the enclosure The three main thermal related systems that we employ are the closed loop cold air supply stream the heat rejection air stream and the vapor compression refrigeration system The clo...

Page 4: ...on as indicated on the shipping container The unit must remain upright for a minimum of 24 hours before initial operation to ensure oil has returned to the compressor Operation before the 24 hour time...

Page 5: ...rm air condenser blower will not operate if the room air temperature is below 80 F 27 C This is due to the fact that the programmable controller has a factory set point of 80 F 27 C The digital displa...

Page 6: ...Error Reference source not found and Error Reference source not found Mechanical Installation Instruction Caution Protective safety clothing such as helmet gloves and steel toe shoes are recommended...

Page 7: ...7 Figure 1 Enclosure Installation Figure 2 Push to Connect Fitting Ambient Side Enclosure Side...

Page 8: ...e Installation Checks 1 Check the air conditioner model label or specification for power requirements 2 Check the designated air conditioner power supply for adequate and proper electrical power requi...

Page 9: ...9 Figure 4 Terminal Block Figure 5 Power Terminal Block...

Page 10: ...ly Closed Red will be installed See Figure 6 Alarm Output Pre Installation Checks 1 Ensure that the power connected to the alarm wires is in an NEC approved Class 2 circuit 2 Check that alarm wire rou...

Page 11: ...ower will continue to operate circulating air within the enclosure The controller has a factory programmed temperature differential of 7 F 4 C Example Cooling On 80 F 27 C Cooling Off 73 F 23 C Ice Qu...

Page 12: ...ng until the enclosure temperature increases approximately 7 F 4 C Press 1 or 2 until the desired set point is displayed within a range of 0 F to 63 F 17 8 C to 17 C Notes Heat is only available with...

Page 13: ...will no longer flash and will show 4 To program the no PIN code mode press 2 and the display will show 0 indicating no PIN code With no PIN code pressing any button will permit access to the program...

Page 14: ...ature must fall 4 F 2 C before the alarm will reset The above alarms can be manually reset by entering the PIN code into the system 3 The filter day timer has expired The Alarm LED lights the display...

Page 15: ...d debris that may cause the system to fail The type of environment will determine the frequency of required maintenance Maintenance of the condensate management system will require access to the botto...

Page 16: ...ompressor and condenser warm air stream blower operating Yes No Is the enclosure door closed tightly Yes No Are all of the gaskets in place Yes No Has the condenser warm air stream filter been cleaned...

Page 17: ...17 Schematic Wiring Diagrams Ordinary Locations 120V 220V 230V Figure 8 IQ350942 Rev A...

Page 18: ...18 Ordinary Locations 400V 460V 480V Figure 9 IQ350943 Rev A...

Page 19: ...19 Hazardous Locations 120V 220V 230V Figure 10 IQ350921 Rev A...

Page 20: ...20 Hazardous Locations 400V 460V 480V Figure 11 IQ350922 Rev A...

Page 21: ...21 Specification Drawing 1000EV Figure 12...

Page 22: ...22 2000EV Figure 13...

Page 23: ...23 3000EV Figure 14...

Page 24: ...24 4000EV Figure 15...

Page 25: ...25 5000EV Figure 16...

Page 26: ...26 6000EV Figure 17...

Page 27: ...27 8000EV Figure 18...

Page 28: ...28 10000EV Figure 19...

Page 29: ...29 12000EV Figure 20...

Page 30: ...30 14000EV Figure 21...

Page 31: ...31 17000EV Figure 22...

Page 32: ...32 20000EV Figure 23...

Page 33: ...33 IQ1 2 3000EV Gasket and Cutout Same Gasket and Cutout for IQ1000EV IQ2000EV and IQ3000EV Figure 24...

Page 34: ...34 IQ4 5 6000EV Gasket and Cutout Same Gasket and Cutout for IQ4000EV IQ5000EV and IQ6000EV Figure 25...

Page 35: ...35 IQ8 10 12000EV Gasket and Cutout Same Gasket and Cutout for IQ8000EV IQ10000EV and IQ12000EV Figure 26...

Page 36: ...36 IQ14 17 20000EV Gasket and Cutout Same Gasket and Cutout for IQ14000EV IQ17000EV and IQ20000EV Figure 27...

Page 37: ...ARRANTY SET FORTH HEREIN IS STRICTLY LIMITED TO ITS TERMS AND IS IN LIEU OF ALL OTHER WARRANTIES GUARANTEES EXPRESS OR IMPLIED ARISING BY OPERATION OF LAW COURSE OF DEALING CUSTOM USAGE OF TRADE OR OT...

Page 38: ...om the date of shipment FCA from Ice Qube s facility in Greensburg Pennsylvania However such in field service is only available at the sole discretion of Ice Qube In field service may not be available...

Page 39: ...M IN FIELD SERVICE THESE UNITS WILL EITHER BE RETURNED TO THE FACTORY FOR REPAIR OR MAY BE ELIGIBLE FOR A REPLACEMENT UNIT THIS WILL BE AT THE SOLE DISCRETION OF ICE QUBE INC Extended Warranty Options...

Page 40: ...40 Notes...

Reviews: