![Ice-O-Matic ICEF 155 Service Manual Download Page 12](http://html1.mh-extra.com/html/ice-o-matic/icef-155/icef-155_service-manual_4093647012.webp)
Page 12
Page 12
NOTE. The ICE LEVEL CONTROL
(INFRA-RED SYSTEM) is independent of
the temperature however, the reliability of
its detection can be affected by external
light radiations or by any sort of dirt and
scale sediment which may deposit
directly on the light source and on the
receiver.
To prevent any possible ice maker
malfunction, due to negative affection of
the light detector, it is advisable to locate
the unit where it is not reached by any
direct light beam or light radiation, also
it is recommended to keep the bin door
constantly closed.
NOTE. During the life of the machine the Ice
Level Control may require a recalibration
mainly when the glass of the two optical eyes
are covered by a thin lay of scale.
To do it just follow the following procedure:
• With unit OFF push and old the Reset
Button of the PC Board
• Give power to the machine through the
Green Master Switch
• Hold the PC Board Reset Button till the
leds start to blink/flash (more or less 10
seconds)
• Release the PC Board Reset Button
The Optical Ice Level Control is now
recalibrated.
Check for the correct operation of the Optical
Ice Level Control by plasing a handfull of ice
in between the two eyes.
The Bin Full yellow led must start to blink/
flash immediately and, 10 seconds later, the
machine must trip OFF.
M. If previously installed, remove the refrigerant
service gauges and re-fit the unit service panels
previously removed.
N.
Instruct the owner/user on the general
operation of the ice machine and about the
cleaning and care it requires.