ICE 1506HR
Remote
1431 (650)
1202 (546)
20.26 (76)
n/a
5.5
20050
208-230/60/1
3
27.4
30
300 (136)
LRC-2661 Remote Condenser for 1 model ICE 1506R (208-230/60/1 voltage)
100 (46)
RT-325-404 25 ft. (7.6m) Precharged Tubing Kit for R-404A models
13 (6)
RT-340-404 40 ft. (12m) Precharged Tubing Kit for R-404A models
18 (8)
RT-345-404 45 ft. (13.7m) Precharged Tubing Kit for R-404A models
19 (9)
RT-360-404 60 ft. (18.2m) Precharged Tubing Kit for R-404A models
23 (12)
ICE
1506
Conds. Air
Temp.
Water
Temp.
°F
(°C)
Unit °F
(°C)
80°(27°)
70°(21°)
50°(10°)
90° (32°)
1118 (508)
1202 (546)
1294 (588)
80° (27°)
1152 (523)
1238 (563)
1362 (619)
70° (21°)
1210 (550)
1301 (591)
1431 (650)
1. 90°/ 70° figures are rated in accordance with
ARI Standard 810. All remaining points are
mathematical estimates.
2. All specifications and performance data are
subject to normal manufacturing variances.
ICE-O-Matic 11100 E. 45th Avenue, Denver, CO 80239
Tel. 303 371-3737 Fax. 303 371-6296 www.iceomatic.com
We reserve the right to make changes in design and construction at any time
without obligation.
2004© ICE-O-Matic Rev Code: 1019B-05/04-SS
Remote
Cooled
Water Used-Gals. (Lits.)
Kilowatts
ICE Production
ICE Production
per 100 lbs. of ICE
Used per
per 24 hrs. at
per 24 hrs. at
90° Air/70° Water
100 lbs. of Ice
Min.
Max.
Shipping
Model
Cond.
70° Air/50° Water 90° Air/70° Water
90° Air
Voltage
No. of
Circuit
Fuse
Weight
No.
Unit
lbs. (Kgs.)
lbs. (Kgs.)
70° Water
Btuh
Characteristics
Wires
Amp.
Size
lbs. (Kgs.)
ICE Prod.
Cond.
Use
Use
60 Hz
ORDERING AND SPECIFICATION INFORMATION
OPERATING LIMITS
Ambient Temp. Range
Remote
-20° - 120°F (-29° - 49°C) 60Hz
Water Temp. Range
40° - 80°F (4.5° - 27°C)
Water Pressure ICE Maker
Min. 20 psi (1.4 bar)
Water in
Max. 60 psi (6.9 bar)
ICE PRODUCTION CHART POUNDS
(KILOGR
AMS) PER
24 HOURS
Ice Cube Dispense Area
7/8" Holes For Electrical
Connections
Ice Maker Potable
Water In 3/8" FPT
Ice Maker Water
Out 3/4" FPT
2.41
11.58
1.09
10.06
13.06
15.56
22.06
Discharge Line 1/2" Male Quick Connect Coupling For
Use With RT-325-404 or RT-340-404 Precharge Line Set
Liquid Line 3/8" Male Quick Connect Coupling For
Use With RT-325-404 or RT-340-404 Precharge Line Set
Rear of Machine
2 x 3.29
2 x 1.10
2 x 1.10
2 x 2.00
2 x 19.50
Ice Maker Potable
Water In 3/8"
Ice Maker Potable Water In 3/8"
(Optional)
Ice Maker Water Out 3/4" FPT
(Optional)
Minimum Wall Clearance
6.00
2 x 4.50
Top View
30.28
Rear of Machine
5.12
20.00
22.05
Hardware For Strap
Mounting To Bin Located
Underside Of Ice Maker
Ice Cube Dispense Area
R.H. Side View
25.61
28.36
22”
(589 mm)
30”
(762 mm)
28 1/2”
(724 mm)
Dimensions
I
S
O
9
0
0
1
C
E
R
T
I
F
I
E
D
®
NOTES
The ICE 1506 must be ordered with the LRC 2661
Remote Condenser. The ERC 2661 is not compatible.
Half Cube
7/8" x 7/8" x 3/8"
(22mm x 22mm x 10mm)
Full Cube
7/8" x 7/8" x 7/8"
(22mm x 22mm x 22mm
)