Ice-O-Matic GEMD270A2 Installation And Service Manual Download Page 19

SETTING THE DISPENSING SELECTOR

Setting the dispensing time

It’s

 

possible

 

to

 

modify

 

the

 

dispensing

 

time

 

to

 

5,

 

10

3  or 

1

.

5

 

seconds.

 

To

 

modify

 

the

 

original

 

setting

 

time

 

(5

 

seconds):

a) Push and hold the 4

th

switch (CONTINUOUS)

for 10 seconds until the first 3 lights start to blink,

b) Push

 

&

 

release

 

the

 

1

st

 

switch

 

(ICE)

 

for

 

a

 1.

5

second dispense.

c) Push & release the 2

nd

switch (ICE AND

WATER)

 

for

 

a

 3 

second

 

dispense.

d) Push

 

&

 

release

 

the

 

3

rd

 

switch

 

(WATER)

 

for

 

a

 

1

.

5

second dispense.

The unit resumes a default dispense setting (Ice,
Ice and Water or Water) after each dispense.

To modify the resume mode (from factory set to
ICE) push the desired switch (ICE, ICE AND
WATER or WATER ) for 5 seconds.

H. CHECK OF THE DISPENSING OPERATING
MECHANISM

To check for the correct operation of the
dispensing mechanism:

a)

First,

 

select

 

the

 

Dispensing

 

Mode

 

by

 

pushing

the

 

proper

 

membrane button

.

b)

Place

 

a

 

glass

 

or

 

a

 

carafe

 

in

 

front

 

of

 

the

 

two

Optical

 

Dispensing

 

Devices.

c)

The

 

dispensing

 

drive

 

motor

 

and/or

 

the

 

water

solenoid

 

valve

 

starts.

 

Ice

 

and/or

 

water

 

is

discharged

 

through

 

the

 

bottom

 

plastic

 

spout.

The drive motor and/or the water solenoid valve
remains in operation (per dispensing time settings)
unless the glass or carafe is removed.

Push the CONTINUOUS switch and check again
for the dispensing mechanism operation per the
steps above.

The drive motor and/or the water solenoid valve
will remain in operation until the glass or carafe is
removed.

I. If connected, remove the refrigerant service
gauges and re-attach the service panels.

J. Instruct the owner/user on the general operation
of the ice machine and its required cleaning and
care.

GEMD270A

Page

 

1

7

Note: If all the dispensing
selector lights are blinking, the
main control board (on the
right side of the unit) has
sensed a problem with the
machine's operation. Check
the main board's diagnostic
lights for further information.

r

Summary of Contents for GEMD270A2

Page 1: ...GEMD270A2 PEARL ICE ICE WATER DISPENSER MODELS GEMD270A2 Installation and Service Manual Ice O Matic 11100 E 45 th Ave Part Number 9081407 01 Revision 03 23 21 Denver Colorado 80239 1 866 PURE ICE...

Page 2: ...SERVICE PARTS MANUAL 22 INCH WIDE ICE SERIES CUBERS MODEL ICE0320 ICE0520 Includes 50Hz Units ICE O Matic 11100 East 45th Ave Denver Colorado 80239 Part Number 9081297 01 PD04 02 Rev1 05...

Page 3: ...ONNECTIONS Page 5 WATER SUPPLY AND DRAIN CONNECTIONS Page 6 FINAL CHECK LIST Page 7 OPERATING INSTRUCTIONS Page 8 INITIAL START UP CONTINUED Page 9 SETTING THE DISPENSING SELECTOR Page 11 PRINCIPLE OF...

Page 4: ...S GEMD270A Page 2 Model Cond unit Cabinet Size Finish Comp HP Ice bin cap GEMD270A Air 34 13 32 high x 15 9 32 wide x 26 7 64 deep S Steel 3 8 12 lb Basic electrical Amps Watts Amps fuse 115 60 1 6 55...

Page 5: ...CABINET DIAGRAMS GEMD270A Page 3...

Page 6: ...including Model and Serial Number taken from the data plate Forward the completed self addressed registration card to Ice O Matic factory LOCATION AND LEVELING WARNING This Ice Dispenser is designed...

Page 7: ...e machine is connected to its own circuit and individually fused see data plate for fuse size Not Connected to a G F I outlet The maximum allowable voltage variation should not exceed 10 and 10 of the...

Page 8: ...ar WATER SUPPLY Connect to the male water inlet fitting using the supplied fitting to the cold water supply line A shut off valve should be installed in an accessible position between the water supply...

Page 9: ...en checked to ensure a flowing water pressure of at least 20 psi 7 Check all refrigerant lines and conduit lines to guard against vibrations and possible failure 8 Has the unit been sealed to the coun...

Page 10: ...the system or inoperativecompressororevaporatorsensor itis necessarytopushtheRE SETBUTTON or De engerizeandre engerizeunit Theunit before resumingthetotaloperation willgothroughthe usual3minutesSTAND...

Page 11: ...compressor F Check for the correct operation of the electronic eye for the ice bin level control by placing one hand between the sensing eyes located in the ice spout to interrupt the light beam This...

Page 12: ...eneous glowing of the YELLOW LED signalling the Full Bin situation NOTE The interruption of the light beam between the two light sensors is immediately signalled by the blinking of the 6th YELLOW LED...

Page 13: ...d coupling a worn shaft or auger placed on its vertical axis within the freezing cylinder The gear motor is made of a single phase electric motor with a permanent capacitor This motor is directly fitt...

Page 14: ...40 psig Suction pressure 1 bar 14 psig REFRIGERANT CHARGE R 134 A 370 gr NOTE Beforechargingtherefrigerantsystem always check the type of refrigerant and quantity as specified on the individual ice ma...

Page 15: ...MANUAL RESET see NOTE The condenser temperature sensor probe located within the condenser fins detects the condenser temperature variations and signals them by supplying current at low voltage to the...

Page 16: ...e towards a rectangular opening located in the bottom of the storage bin Elapsed the dispensing time 5 10 or 15 seconds according to the setting or after removing the glass carafe the infrared resume...

Page 17: ...owing instructions Switch OFF the machine Push and hold the PC Board push button Switch ON the machine keepiung pushed the PC Board push button till all LEDs are ON Release the push button ALL STEADY...

Page 18: ...earings permanently lubricated The gear case contains a train of three spur gears the first one of which is in fiber to limit the noise level All the three gears are encased in case bearings and are c...

Page 19: ...ing the proper membrane button b Place a glass or a carafe in front of the two Optical Dispensing Devices c The dispensing drive motor and or the water solenoid valve starts Ice and or water is discha...

Page 20: ...ps Check for correct operation of drive after a while motor magnetic sensor Check for correct magnetic capacity of magnetic cylinder Compressor cycles intermittently Low voltage Check circuit for over...

Page 21: ...st float valve setting screw Excessive noise or chattering Mineral or scale deposit on auger Remove and manually polish auger and inner freezer walls and inner walls of freezer barrel using emery pape...

Page 22: ...p of a bit of ice machine cleaner plain 7 With the ice machine and fan motor OFF clean condenser using vacuum cleaner whiskbroom or non metallic brush taking care to do not damage the condenser temper...

Page 23: ...ored It may also loose fluidity creating some resistance in being elevated and extruded this situation can be heard by the creaking noise made by the ice If this should occur it is recommended that yo...

Page 24: ...n 11 Remove nut holding bin to chassis 12 Pull bin out of machine 13 Remove screws holding air deflector to chassis and pull deflector out of the unit 14 Remove screws holding reservoir to bulkhead pa...

Page 25: ...ace large washers over coupling and small washer under bottom of bearing Insert bolt through large washers coupling and bearing Run one nut into bearing to center the bolt Add small washer and nuit Ti...

Page 26: ...e thrust bearing and place it on top of the roller bearing The inner race of the roller bearing must project through the center of the flat thrust bearing 9 Install the flat washer provided with the n...

Page 27: ...ring and bottom seal Rotating Half 1 Remove old rotating half from the auger Clean the mounting area 2 Place a bead of food grade sealant onto the shoulder of the auger where the rotating half of the...

Reviews: