GEM-MFI SERIES
For the Installer (Check List)
Page 17
Final Check List: Air and Water Cooled
_______1. Is the ice machine installed indoors in a location where the air and water temperatures are
controlled and where they do not exceed the design limitations?
_____2. Is there an electrical service disconnect within sight of the installed machine?
_____3. Has the voltage been checked and compared to the nameplate requirements?
_____4. Have all the plumbing connections been made and checked for leaks?
_____5. Is the ice machine and storage bin level?
_____6. Is there a minimum of 6 inches of clearance at the back of the machine for proper service
access and air circulation?
_____7. Is the water pressure a minimum of 20 psig?
_____8. Has the ice machine been secured to the bin?
_____9. Is there clearance over the top of the ice machine for service access?
____10. Is there a water shut off valve installed near the ice machine?
Note: Fasten the ice machine
to the bin with the hardware
supplied with the ice machine
Insure the machine is level