Ice-O-Matic GEM Series Installation, Start-Up And Maintenance Manual Download Page 9

GEM-MFI SERIES 

 

For the Installer (Applications) 

 

Page 5 

 

Bin Application 

The GEM-MFI Series is designed to fit the following Ice-O-Matic Bins 
●B42, using Bin Top KBT 24  
●B25, B40 or B55 using Bin Top KBT 19. 
●B110, using Bin Top KBT 23 (one unit) or KBT 222 (two units). 
●B700-30, B1000-48, B1300-48, B1325-60, B1600-60 

Dispenser Application 

The GEM Series can be placed on and used with certain ice and beverage dispensers listed below.  Kits are required for 
proper operation.  The MFI Series is not approved for dispenser application. 
 

Dispenser 

GEM0450 GEM0650 
GEM0956 GEM1306A/R 

GEM2006R

ICE-O-Matic IOD150 

KKGEMDISP 

N/A 

ICE-O-Matic IOD200 or IOD250 

KKGEMDISP 

KKGEMDISP 

Cornelius ED or DF150 

KR629088514* 

N/A 

Cornelius ED or DF200 

KKGEMDISP 

KKGEMDISP 

Cornelius ED or DF250 

K KGEMDISP 

KKGEMDISP 

Cornelius ED300 

K629087966* 

KKGEMDISP 

Cornelius Flavor Fusion 255 

KDIL-N-CFF and Cornelius 
adapter 629088681 (Black) 

Consult dispenser 
manufacturer 

Lancer  (Must have N in part 
number) 30 inch 4500 model 

KDIL-N-L and Lancer Part 
Number 82-3491 

Consult dispenser 
manufacturer 

* Cornelius Part Number

, If the Dispenser Model is Not Listed above, then is it NOT APPROVED

 

All the dispensers have automatic agitation to keep the ice from clumping.  If agitation is too frequent, the Pearl Ice will be 
damaged and will become difficult to dispense.  The Ice-O-Matic and Cornelius dispensers need to be set to 2 seconds on 
every 3 hours and the Lancer needs to be set to 4 seconds on, 150 seconds off. 

The Ice-O-Matic and most Cornelius dispensers also have a restrictor plate at the outlet of the hopper. When used, that plate 
should be adjusted to be 1.5 inch open to limit the speed of the Pearl Ice flows out during dispensing. 

Ice Machine Specifications 

Model 
Numbers 

WxDxH (in.) 

Basic Electrical 

Condenser 

Min. Circuit 
Ampacity 

Max. Fuze 
Size 

Refrigerant  
Charge oz. 404a 

GEM0450A 

21x24x27 

115/60/1 

Air 

15.75 

20 

22 

GEM0450W 

Water 

14.35 

20 

18 

GEM0650A 

Air 

19.50 

30 

24 

GEM0650W 

Water 

18.30 

30 

19 

GEM0650R 

RGA0501-HM 

22.50 

30 

208 

GEM0956A 

208-230/60/1 

Air 

11.30 

15 

30 

GEM0956W 

Water 

10.80 

15 

22 

GEM0956R 

RGA1061-HM 

14.10 

20 

208 

GEM1306A 

Air 

15.80 

20 

30 

GEM1306R 

RGA1061-HM 

17.40 

20 

208 

GEM2006R 

30x24x27 

RCA2061 

24.40 

40 

208 

MFI0500A 

21x24x27 

115/60/1 

Air 

15.75 

20 

22 

MFI0500W 

Water 

14.35 

20 

18 

MFI0800A 

Air 

19.50 

30 

24 

MFI0800W 

Water 

18.30 

30 

19 

MFI0800R 

RGA0501-HM 

22.50 

30 

208 

MFI1256A 

208-230/60/1 

Air 

11.30 

15 

30 

MFI1256W 

Water 

10.80 

15 

22 

MFI1256R 

RGA1061-HM 

14.10 

20 

208 

MFI1506A 

Air 

15.80 

20 

30 

MFI1506R 

RGA1061-HM 

17.40 

20 

208 

MFI2306R 

30x24x27 

RCA2061 

24.40 

40 

208 

 

Summary of Contents for GEM Series

Page 1: ...Installation Start up and Maintenance Manual GEM MFI Series 60 hz Ice O Matic 11100 East 45th Ave Denver Colorado 80239 Part Number 9081403 01 Rev G...

Page 2: ...Always wear protective eyewear and gloves whenever maintenance or repairs are performed on the ice machine and related equipment Sustainability Program Ice O Matic is devoted to sustainability in ever...

Page 3: ...taller Guidelines Page 1 For The Installer Applications Page 5 For The Installer Location Page 6 Remote Condenser Page 7 For The Plumber Page 12 For The Electrician Page 14 For The Installer Completed...

Page 4: ...for carrier s inspection Visible Loss or Damage Any external evidence of loss or damage must be fully described and noted on your freight bill or express receipt and signed by the carrier s agent Clai...

Page 5: ...not recommended Route bin drain vented float overflow drain and water condenser drain individually to a floor drain The use of condensate pumps for draining water is not recommended by Ice O Matic Ice...

Page 6: ...GEM MFI SERIES For the Installer Guidelines Page 2 21 Air and Water Cooled...

Page 7: ...GEM MFI SERIES For The Installer Guidelines Page 3 21 Remote...

Page 8: ...GEM MFI SERIES For The Installer Guidelines Page 4 30 Remote...

Page 9: ...T APPROVED All the dispensers have automatic agitation to keep the ice from clumping If agitation is too frequent the Pearl Ice will be damaged and will become difficult to dispense The Ice O Matic an...

Page 10: ...too far forward on the bin the opened door may not be stable resulting in an unexpected closing of the bin door If the ice machine is to be mounted on a bin or dispenser other than an Ice O Matic refe...

Page 11: ...on locates the ice machine indoors but in a place where the heat and noise it produces are not objectionable Air cooled machines discharge hot air out the back and must have a minimum of 6 inches of c...

Page 12: ...hd x 1 hd distance in feet Calculation Drop s Rise s Horizontal Run dd rd hd Calculated Line Length Configurations that do NOT meet these requirements must receive written authorization from Ice O Ma...

Page 13: ...for connecting information 1 Each set of preharged tubing refrigerant lines consists of a 3 8 diameter liquid line and a 1 2 inch diameter discharge line Both ends of each line have quick connect cou...

Page 14: ...GEM MFI SERIES Remote Condenser Page 10 Typical Installation REMOTE CONDENSER ICE MACHINE...

Page 15: ...the swivel nuts by hand until it is certain that the threads are properly engaged 4b Using two wrenches one to rotate the swivel nut and one to hold the tubing tighten each coupling It is CRITICAL th...

Page 16: ...ent should be followed Drains Air Cooled Models Connect a rigid drain tube to the FPT drain fitting at the back of the cabinet The drain is a gravity type and a inch per foot fall is the minimum accep...

Page 17: ...s Remote Cooled Models There is one 3 4 inch FPT drain at the back of the cabinet the drain line is of the gravity type and 1 4 inch per foot fall is an acceptable pitch for the drain tubing There sho...

Page 18: ...is to earth ground Connect the ice machine to its own electrical circuit so it is individually fused Voltage variation must remain within the limitations even under starting conditions Note All extern...

Page 19: ...imitations even under starting conditions There is a separate junction box for the remote condenser fan motor Install an interconnecting wire between the remote condenser and the junction box at the b...

Page 20: ...age 16 Completed Installation Remote Condenser Roof Cut A Way Remote Line Set Ice Machine A typical installation should generally appear as illustrated below The best place for the remote condenser is...

Page 21: ...ments _____4 Have all the plumbing connections been made and checked for leaks _____5 Is the ice machine and storage bin level _____6 Is there a minimum of 6 inches of clearance at the back of the mac...

Page 22: ..._6 Is the water pressure a minimum of 20 psig ___7 Has the machine been secured to the bin or dispenser ___8 Is there a water shut off valve installed near the machine ___9 Is the remote condenser ins...

Page 23: ...On air cooled models the condenser will begin to discharge warm air on water cooled models the water regulating valve will open and warm water will be discharged into the drain 5 The unit should soon...

Page 24: ...the King Valve 4 Switch the master switch ON The electrical start up sequence in automatic a There should be a short 15 second delay before the gear motor starts and the liquid line opens b After the...

Page 25: ...ice machine and or Bin Dispenser perform the following 1 Remove the ice machine front panel 2 Turn the machine OFF at the ON OFF selector switch 3 Remove all ice in the storage bin Required for cleani...

Page 26: ...Questions Ice O Matic Ice Machine Bin Cleaning Cleaning or de liming an ice machine refers to the process of removing mineral buildup and scale from the evaporator and other components Ice O Matic rec...

Page 27: ...b When cleaning the Condenser check the fan blade for cleanliness and for balance Balance is checked by spinning the blade by hand and looking for any wobble Pull on the shaft in several directions to...

Page 28: ...brush Disconnect electrical power and remove the air filter if applicable The filter may be cleaned or replaced Clean the condenser the condenser may appear to be clean on the surface but it can stil...

Page 29: ..._________________ ________________________________________________________________________________________ ________________________________________________________________________________________ ____...