Iccons GT6-IXF User Manual Download Page 10

10

ICCONS® GAS TOOL GT6-IXF USER MANUAL

6  Troubleshooting

WARNING:

To reduce the risk of serious 
personal injury, ALWAYS unload 
the battery, the nails and fuel 
cell from the tool before all 
repairs.

6.1  Battery/Charger Problems

SYMPTOM 1

Battery Cell does not appear to accept 
charge. Green charger light does not come on 
after several hours.

Possible 

reasons

Services

Inoperative 
indicator lights 
on charger.

Try Battery in tool after 
1 hour on charge cycle. 
If tool functions properly 
charger lights are not 
working correctly. Replace 
charger, or monitor time 
to ensure Battery Cell 
has adequate time for 
recharging. It’s normal for 
Battery to feel warm after 
properly charging.

Damaged 
charger.

Discontinue use 
immediately and unplug 
from power source. 
Replace charger and tag 
or dispose of charger to 
prevent accidental reuse 
or connection to power 
source.

SYMPTOM 2

Red L.E.D on charger is blinking.

Possible 

reasons

Services

Battery is hot.

Remove battery from 
charger and allow to cool. 
Inspect battery charger 
and cartridge.

SYMPTOM 3

Orange L.E.D on charger is blinking.

Possible 

reasons

Services

Charger 
Damaged

Replace Charger.

6.2  Normal Stage of Operation

SYMPTOM 1

Fan does not run.

Possible 

reasons

Services

Battery is not 
charged.

Charge Battery according 
to Operating Manual.

Battery 
Terminals or 
Handle battery 
contacts are 
oily, dirty, or 
corroded.

Clean Battery Cell 
terminals, Clean Tool 
Battery Cell contacts as 
required.

There is 
electrical short 
somewhere.

The tool must be 
assessed by Authorized 
Service / Repairer.

SYMPTOM 2

Fan does not run, or runs slower than normal.

Possible 

reasons

Services

Battery is 
discharged.

Charge Battery Cell.

SYMPTOM 3

Fan runs intermittently.

Possible  

reasons

Services

Battery is loose 
or contacts are 
bent.

Snap battery back into 
its locked position. Bend 
contacts back into proper 
position.

Summary of Contents for GT6-IXF

Page 1: ...190813 rev 1 USER MANUAL GT6 IXF GAS TOOL...

Page 2: ...1 Symbols Used In This Operating Manual 3 2 General Safety Instructions 3 2 1 2 2 2 3 2 4 2 5 Introduction Safety Of The Fastening Tool Safety At Work Safety For Handling Fasteners Safety For Gas Ope...

Page 3: ...Introduction Only those fasteners which are specified in the operating instructions shall be used in the tool The tool the fastener the fuel cell and the battery specified in the operating instructio...

Page 4: ...Do not load the fasteners with the trigger and or work contacting element pressed Ensure that you use the correct length of fastener with the depth adjuster correctly set so that nails do not protrud...

Page 5: ...Rail ADR RID UN code 2037 class 2 1 Sea IMDG UN code 2037 class 2 1 EmS F D S U Air IATA UN code 2037 class 2 1 Goods must be accompanied by a transport emergency card for road UN 2037 Transport by po...

Page 6: ...lly charged the batteries if stored for a long time Recharge it in each 3 months can help to compensate the self discharged and keep the battery in a good condition The charging systems should store a...

Page 7: ...charger or battery cartridge The battery charger is for charging specific battery pack Never attempt to charge battery pack from other manufacturer s battery cartridge Unsuitable battery cartridges ma...

Page 8: ...cell Remove fasteners from the magazine on the tool before installing fuel cell Do not depress tool on any surface ground while installing Steps 1 Open the flap 2 Insert the fuel cell make sure the ru...

Page 9: ...d nail guide 4 To install the magazine first engage the magazine in the slot of the nose piece 5 Push the connecting plate into the handle until it clicks NOTE Do not release the magazine with fastene...

Page 10: ...tal reuse or connection to power source SYMPTOM 2 Red L E D on charger is blinking Possible reasons Services Battery is hot Remove battery from charger and allow to cool Inspect battery charger and ca...

Page 11: ...Services Piston positioned wrongly Return piston to original position with a rod or screwdriver O Ring is damaged and causing leakage of gas Contact authorized service agent for repair Damaged valve p...

Page 12: ...after tool cycles Possible reasons Services Contact arm is bent or tool is dirty Clean tool or replace contact arm as require Possible reasons Services Fuel Cell is low Replace fuel cell according to...

Page 13: ...stener Dimensions Nail Head Diameter 6 3 mm Nail Length 13 45 mm Shank Diameter 2 6 3 7 mm Applications Steel to Steel 3 0 mm step Steel Plate to Concrete 2 6 3 7 mm Steel Plate to Hard Concrete 3 0 m...

Page 14: ...14 ICCONS GAS TOOL GT6 IXF USER MANUAL 9 Parts List...

Page 15: ...SEMBLY FS2 62 18 362 0 HEAD ASSEMBLY FS2 63 01 065 0 SPARK PLUG 64 17 048 0 FUEL NOZZLE 65 01 067 0 MOTOR SLEEVE 66 17 042 0 MOTOR BUMPER M25 POS CODE DESCRIPTION 67 17 043 3 MOTOR M4 68 17 044 0 MOTO...

Page 16: ...16 ICCONS GAS TOOL GT6 IXF USER MANUAL...

Page 17: ...onsequential damages resulting from the improper use of the tool The national safety and occupational safety regulations and the safety precautions given in this operating manual must be observed when...

Page 18: ...MAGE ICCONS ENTIRE LIABILITY IS LIMITED TO THE PURCHASE PRICE OF THIS PRODUCT If you wish to make a warranty claim then the tool or part must be returned to ICCONS Pty Ltd at the owner s expense ICCON...

Page 19: ...ctoria 3175 Australia Tel 61 03 9706 4344 Fax 61 03 9768 3329 Email info iccons com au Web www iccons com au This manual must be observed when using the tool All product designations and brand names a...

Page 20: ......